INSTALLATION

CLEANING INSTRUCTIONS

All Finishes: Clean the finish with mild soap and warm water. Wipe entire surface completely dry with clean soft 

cloth. Many cleaners may contain chemicals, such as ammonia, chlorine, toilet cleaner etc. which could adversely 

affect the finish and are not recommended for cleaning.

Do not use abrasive cleaners or solvents on Kohler faucets and fittings. 

INSTALLATION CHEKOUT

How to Install the Faucet

To perform installation, installer must provide G1/2

˝ 

female supply 

fittings(1), spaced 150mm apart and horizontally. The supply fittings 

should be vertical and not beyond the finished wall. Hot supply pipe must 

be located on the left.

Install the two offset connectors(2) into the hot and cold supply pipes. 

Use appropriate thread sealants or thread tape on pipe threads.

Adjust the center-to-center distance between the connectors to 150mm 

and horizontally. They should extend 36 to 47mm beyond the finished 

wall. 

Slide the escutcheons(3) onto the nuts(4). Put the washers(5) into the 

nuts, thread the nuts to connectors. Tighten the nuts with strap wrench or 

soft cloth between product and regular wrench. Push the escutcheon 

against the finished wall.

How to Install the Shower Column

Rehearse the slide bar kit(6) installation for the anchor(7) mounting 

location determination. Install the slide bar kit onto the faucet by the 

pin(8). Place the connector(9) against the finished wall. If not, make it 

against the finished wall by loosening or tightening the connector. Mark 

the outline of the bottom of the connector and the center point of the 

outline with a pencil on the wall. 

Drill a hole on the center point as the anchor diameter. Press the anchor 

into the hole. Secure the mounting board(12) by the self-tapping 

screw(10) with the washer(11). 

NOTE: 

Orient the side with round groove on the mounting board against 

the finished wall. 

Slide the escutcheon(13) onto the connector(9). Install the slide bar kit 

onto the faucet by the pin, and install the connector(9) onto mounting 

board. Tighten the screw(15) with the hex wrench(14). Tighten the 

screws(17) with the hex wrench(16). Push the escutcheon(13) against the 

finished wall, and tighten the screw(18) with the hex wrench(14).  

How to Install the Handspray and the Hose

Turn the diverter handle(19) to the handspray logo and run hot and cold 

water for about one minute to remove any debris.

Remove the guards on the outlet connectors of the hose(20). Install the 

check valve(23) into the handspray(22) inlet if needed. Tighten one 

connector(20-1) of the hose to the connector(21). Remove the washer 

from another connector(20-2), replace with the washer(24). Tighten the 

connector(20-2) of the hose to the handspray(22).

Ensure that all connections are tight. Ensure that the handles are in the off position. 

Turn on the drain and main water supply, and check for leaks. Repair as needed.

How to Install the Showerhead

Turn the diverter handle(19) to the showerhead logo and run hot and cold 

water for one minute to remove any debris before the showerhead(25) is 

installed. 

Tighten the showerhead onto the outlet(26) with strap wrench.

Before installation, install the restrictor(27) if needed. Take out the 

washer(28) and install the restrictor as the figure shown, reinstall the 

washer.

3

2

1

Hot

Cold

150mm

36~47mm

4

5

Hot

Cold

14

7

6

8

9

10

12

11

13

15

16

17

18

Center Point

21

20

20-1

20-2

22

19

23

24

25

26

27

28