1145740-T01-B
-3-
(
)
!
!
!
NOTE:
For Retrofit Installations
For New Installations
If a pre-existing waste pipe will be used and will result
in an acceptable rim height (refer to the rough-in dimensions),
follow the retrofit installation instructions.
Turn the water supply line off, remove the existing urinal,
then cap off the water supply line inside the wall.
Install waste pipe as necessary to conform to the
roughing-in dimensions.
Install adequate support framing for the hangers as
needed.
!
!
!
Wall Hangers
Wall
Hangers
Fig.2
2
PREPARE THE SITE
PREPARE THE SITE
Panel, Nozzle
Cap
Gasket
Collar
Washer
Bolt
Waste Pipe
Apply Sealant Tape
Notice:
To ensure an effective flush performance,
strongly recommended inner diameter of
water supply (including water meter, valve,
etc.) is no less than 25mm, and supplied
water pressure (sensor inlet dynamic
pressure) is 0.18MPa ~0.55MPa.
(
)
25mm
(
)
0.18MPa ~0.55MPa
A. Install hook
Drill 2 mounting holes on the wall and install hook. Fix hook
on the wall by tightening screws.
A.
INSTALLATION
Fig.3
3
Wall Hangers
Wall