background image

No change in measurements if connected
with drain illustrated. (K-7166-AF)

Blower Access
20" (508 mm) W x
15" (381 mm) H

3-1/4"
(83 mm)

11"
(279 mm)

21-1/8"
(537 mm)

3-5/8"
(92 mm)

2-7/8"
(73 mm)

3"
(76 mm)

1-1/2" Bath Drain

1" (25 mm)

1-1/4"
(32 mm)

21"
(533 mm)

60" (1524 mm)

42-1/4" (1073 mm)

Lumbar
Angle 14°

Notes

Required Electrical Service

Measure your actual product for rough-in details.

One dedicated circuit required, protected with Class A
Ground-Fault Circuit-Interrupter (GFCI). Outside North America,
this device may be known as a Residual Current Device (RCD).

Install this product according to the installation
instructions.

The hot water supply should be 70% of the
capacity of the bath or greater. Installations will
vary.

120 V, 15 A, 60 Hz

Blower:

Technical Information

All product dimensions are nominal.

Provide one grounded electrical outlet within 24"
(610 mm) of each component.

Drop-in

Installation:

End

Drain location:

Remote blower installation kit K-1446 is available
for relocating the blower. Provide access for
servicing the blower.

42" x 28" (1067 mm x 711 mm)

Basin area, bottom:

55" x 40" (1397 mm x 1016 mm)

Basin area, top:

Do not relocate or alter the PVC tee or coiled
flexible tubing connected to the blower. Follow
the blower relocation instructions exactly.

87 lbs (39.5 kg)

Weight:

41 lbs/ft² (200.2 kg/m²)

Minimum floor load:

15-1/2" (394 mm)

Water depth:

73 gal (276.3 L)

Water capacity:

Drop-in, 1017044-7, required, included

Template:

Blower: 120 V, 10 A, 60 Hz

Electrical component

rating:

1-800-4KOHLER (1-800-456-4537)
Kohler Co. reserves the right to make revisions without notice to product specifications.
For the most current Specification Sheet, go to 

www.kohler.com

.

2-10-2020 07:48 - US

Serif

®

5' BubbleMassage

 Bath

K-1337-G