3. Connect the Supplies
CAUTION: Risk of restricted water flow and product damage.
Supply hoses must not be taut, kinked, or twisted during
installation. If the supply hoses must be coiled, maintain an inside
diameter (ID) of 3
″
(76 mm).
CAUTION: Risk of fresh water contamination.
To prevent water
contamination, the check valves must be installed.
Connect the Supplies
Assemble a check valve to each supply.
Connect and tighten the supply hoses to the check valves.
Place a bucket under the outlet hose.
Turn on the supplies.
Flush the hot and cold water for 1 minute to remove any debris.
Connect the outlet hose to the solenoid inlet.
Connect the Spray Hose
Remove the protective cap.
Solenoid
Weight
Outlet Hose
Ø 3"
(76 mm)
Min
Supply Hose
Check
Valve
Outlet
Hose
Inlet
Outlet
Spray
Hose
1384293-2-B