H. Adjust Inlet Valve
Hoist and reduce the water level in the tank by adjusting
the control pole. Turn the control pole counterclockwise to
lower down the floating box and reduce the water level of
the tank. Turn the control pole clockwise to hoist the
floating box and increase the water level in the tank
H.
G. Adjust Drainage Valve
Drainage volume and overflow level of the tank can be
adjusted by drainage valve: 1) Heavy drainage adjustment:
Open adjustment switch to open the small hole. 2) Slight
drainage adjustment: adjust the height of floating box and
the water level of slight drainage will be at the bottom of
the floating box.
G.
(1)
(2)
Control Pole
Drainage Valve
Adjustment Switch
Floating Box
-17-
Floating Box
Adjustment Switch
1048671-T01-K