background image

1

ROUGHING-IN & DIMENSIONS

•  Please read these instructions carefully to familiarise 

yourself with the required tools, materials, and 

installation sequences. Follow the sections that 

pertain to your particular installation. This will help 

you avoid costly mistakes. In addition to proper  

installation, read all operating and safety instructions.

•  All information is based on the latest product 

information available at the time of publication. 

Kohler NZ Ltd. reserves the right to make changes in 

product characteristics, packaging, or availability at 

any time without notice.

•  These instructions contain important care, cleaning,  

and warranty information-

�������������������

������������������������������

A. BUBBLE MASSAGE BATH 

Ordering Information

REGATTA drop in 

B. Required Electrical Service

Dedicated branch circuit required, protected with Class 

A Ground-Fault Circuit-Interrupt (GFCI):
Blower

220~240V, 10.A, 50Hz 

C. Installation

Read the entire installation instructions before beginning 

the installation.

BEFORE YOU BEGIN

BUBBLE MASSAGE BATH

INSTALLATION INSTRUCTIONS

1128227-A01-D   Date: 13/8/2010   

Blower

Heater Voltage

Freq

Amperage

Motor

Part #

Kohler AP300  - air switch

300 W

180W 220~240 V 50-60Hz 2.2A

1128A-CP

Product

Air switch 

11303A-GAB-0

EVOK RECT drop in 
EVOK RECT freestanding
EVOK OVAL drop in 

18344A-GAB-0

18263A-GAB-0

18346A-GAB-0

EVOK OVAL freestanding

18348A-GAB-0
1709A-GAB-0

ESCALE drop-In
ESCALE free Standing

11343A-GAB-0
11344A-GAB-0

OVE RECT drop in 

D. Dimensions

Detached blowers are supplied with a 1.5m flexible coupling. This allows the blower to be positioned at the installers 

discretion. For serviceability of the blower, an access panel of 450mm x 400mm must be fitted.  If access to the 

blower is not provided, then no warranty service will be provided.

If supply cord or interconnection cord is damaged, it must be replaced by the manufacturer, its service agent or

similarly qualified persons in order to avoid a hazard.  

Содержание OVE RECT drop in 1709A-GAB-0

Страница 1: ...10 A 50Hz C Installation Read the entire installation instructions before beginning the installation BEFORE YOU BEGIN BUBBLE MASSAGE BATH INSTALLATION INSTRUCTIONS 1128227 A01 D Date 13 8 2010 Blower...

Страница 2: ...2 REGATTA BUBBLE MASSAGE 11303A GAB 0 1128227 A01 D Date 13 8 2010 OVE BUBBLE MASSAGE 1709A GAB 0 50...

Страница 3: ...3 1128227 A01 D Date 13 8 2010 EVOK BUBBLE MASSAGE 18263A GAB 0 EVOK RECT FREESTANDING BUBBLE MASSAGE 18344A GAB 0 50 837 5 1675 762 408 5 50 36 513 610 81...

Страница 4: ...4 1128227 A01 D Date 13 8 2010 EVOK OVAL BUBBLE MASSAGE 18346A GAB 0 EVOK OVAL FREESTANDING BUBBLE MASSAGE 18348A GAB 0 398 750 50 1700 850 39 50 510 610 398 750 50 1700 850 50 530...

Страница 5: ...5 ESCALE DROP IN BUBBLE MASSAGE BATH 11343A GAB 0 1128227 A01 D Date 13 8 2010 ESCALE FREESTANDING BUBBLE MASSAGE BATH 11344A GAB 0...

Страница 6: ...or property damage Please read all instructions thoroughly before beginning installation including the following Product Requirements WARNING Keep the area around the blower motor clean and free of de...

Страница 7: ...g Install an access panel to allow the pump to be serviced Bath may be installed next to the Bath rim must be fully supported wall or as an island installation Tile Brick or timber B Whirlpool Area Co...

Страница 8: ...TALL THE BATH CAUTION Risk of product damage Do not lift the bath with airjets by the air channels or blower motors or use the air channels or blower motor for structural support of the bath CAUTION R...

Страница 9: ...ion Insert the drain tailpiece into the trap Make sure the bath is level and resting on all support blocks Remove the protective tape from the rim Apply a continuous bead of high quality silicone seal...

Страница 10: ...d with a cord and plug A licensed electrician must install a dedicated GFCI protected 220V 10A grounded outlet Locate the outlet behind the bath and within 610mm of the blower motor Plug the blower mo...

Страница 11: ...im is fully supported Build the bath support frame as shown When the bath is securely positioned before the unit is fully built in install tapware connect plumbing to Run water into the bath and check...

Страница 12: ...Do not use powdered cleaners unless the cleaner is fully dissolved in water Solid substances could block the airjets Do not use bleach or ammonia cleaning solutions Chemically active cleaning solution...

Страница 13: ...move air switch tube and drain C Air switch is faulty or disconnected C Check air tube connections D Blower motor does not work D Replace blower motor 2 Blower motor starts but there are few or no bub...

Страница 14: ...information please visit our website Australia www au kohler com New Zealand www kohler co nz CONTACT AND WARRANTY INFORMATION 1034122 FJ Check Valve Air switch and blower 1128A CP 1122542 80mm Level...

Страница 15: ......

Отзывы: