INSTALLATION CHECKOUT

CLEANING INSTRUCTIONS

All Finishes: Clean the finish with mild soap and warm water. Wipe entire surface completely dry with clean soft 

cloth. Many cleaners may contain chemicals, such as ammonia, chlorine, toilet cleaner etc, which could adversely 

affect the finish and are not recommended for cleaning.

Do not use abrasive cleaners or solvents on Kohler faucets and fittings. 

INSTALLATION

NOTE: 

Install mounting box 

kit(1) according to the rough-in               

dimensions of 98699T-NA. 

Cut the protrudent part of the 

mounting box kit out of the 

finished wall. Unscrew the 

screw(2), remove the protect 

cover kit(3).

Remove the protection(5) on the valve 

kit(4). 

NOTE: 

Don’t drop the 

o-rings(6), don’t turn the cartridge 

spindle(7) when install it. The holes on 

the bottom of the valve kit should be 

aligned with the holes in the mounting 

box. Install the valve kit into the 

mounting box kit, tighten the 

screws(8).
Slide the cover kit(9) onto the valve. 

Push it against the wall. Secure it with 

the screws(10).

Slide the faceplate(11) onto the valve 

with slots(12) downwards. 

NOTE:

 

Don’t squeeze out the rings(13,14). 

Push it against the wall. 

Install the handle(15,16) on the 

cartridge spindle with handle vertically 

upward.

The illustration shown is the correct position of the handles in the closed position.

Ensure that all coupling nuts are tight. Ensure that the handle is in the off position.

 

Turn on the main water supply, and check for leaks. Repair as needed.

1

2

3

Ring

Stop Assembly

Cartridge

1

Screw

TH handle

Notch

3

The temperature is set by slowly turning the temperature handle at underside. For safety reasons, there is a stop 

that limits temperature to 37ºC. To get a higher temperature, push the button and continue turning the temperature 

handle.
Water flow is set by turning the top flow handle. 

OPERATION INSTRUCTION

Temperature Verification and Setting

Make sure that the water feeds of the faucet have reached their highest temperature but within the recommended 

range by letting the water run sufficiently. With the selector in position 37ºC, the temperature of the water coming 

out of the faucet must be within a range of 36ºC and 38ºC, as measured by a thermometer. If the temperature out 

of the range, the installer can adjust the setting. Proceed with the setting as follows:

Remove the temperature handle kit.

With the faucet on "cold" normal water flow, slowly turn the temperature selector(always in the same direction) until 

water at 37ºC is obtained. If the temperature goes over 37ºC, go back to the “cold” setting and set again.

When the temperature is stabilized, do not turn the cartridge spindle, reinstall the handle kit. 

Clean Thermostatic Cartridge

Very hard water can obstruct the filters on thermostatic cartridge and reduce the flow of water. Please clean the 

cartridge as follows:

Shut off  the water supplies of the faucet and open the flow valve, then proceed to remove the cartridge. The 

cartridge is sense part, please be careful.

Make sure the handle is aligned with the number 37 on faceplate before your action. Remove the temperature 

handle kit. Remove stem, detent and stop assembly(Fig.1). Removing the thermostatic cartridge cautiously(15). 

Clean the thermostatic cartridge by soaking it in warm vinegar.

After cleaning, make sure that the black dot is correctly in line with the black line. Install the “stop assembly” back 

on the cartridge, adjusting the stop pin into the notch(Fig.2). Install the cartridge and stop assembly into the body, 

adjusting the stop pin into the notch(Fig.3). Reinstall the ring and screw. Reinstall the temperature handle kit and 

align the handle to the “37” on the faceplate.

CARE AND MAINTENANCE

Notch

Stop Pin

2

Black Dot
Black Line

4

7

8

9

10

5

6

4

NOTE: 

If the hot and cold water supplies are connected inversely, 

installer must exchange the position of the hot and cold insert assy. 

Ensure the product works properly.

Insert assy(Cold)

Insert assy(Hot)

78023T-4                             78024T-4                           78023T-4A                           78024T-4A

11

12

14

15

16

13