1301217-2A-A
2
1301217-2A-A
3
INSTALLATION CHECKOUT
CLEANING INSTRUCTIONS
All Finishes: Clean the finish with mild soap and warm water. Wipe entire surface completely dry with clean soft
cloth. Many cleaners may contain chemicals, such as ammonia, chlorine, toilet cleaner etc, which could adversely
affect the finish and are not recommended for cleaning.
Do not use abrasive cleaners or solvents on Kohler faucets and fittings.
INSTALLATION
NOTE:
Install mounting box
kit(1) according to the rough-in
dimensions of 98699T-NA.
Cut the protrudent part of the
mounting box kit out of the
finished wall. Unscrew the
screw(2), remove the protect
cover kit(3).
Remove the protection(5) on the valve
kit(4).
NOTE:
Don’t drop the
o-rings(6), don’t turn the cartridge
spindle(7) when install it. The holes on
the bottom of the valve kit should be
aligned with the holes in the mounting
box. Install the valve kit into the
mounting box kit, tighten the
screws(8).
Slide the cover kit(9) onto the valve.
Push it against the wall. Secure it with
the screws(10).
Slide the faceplate(11) onto the valve
with slots(12) downwards.
NOTE:
Don’t squeeze out the rings(13,14).
Push it against the wall.
Install the handle(15,16) on the
cartridge spindle with handle vertically
upward.
The illustration shown is the correct position of the handles in the closed position.
Ensure that all coupling nuts are tight. Ensure that the handle is in the off position.
Turn on the main water supply, and check for leaks. Repair as needed.
1
2
3
Ring
Stop Assembly
Cartridge
1
Screw
TH handle
Notch
3
The temperature is set by slowly turning the temperature handle at underside. For safety reasons, there is a stop
that limits temperature to 37ºC. To get a higher temperature, push the button and continue turning the temperature
handle.
Water flow is set by turning the top flow handle.
OPERATION INSTRUCTION
Temperature Verification and Setting
Make sure that the water feeds of the faucet have reached their highest temperature but within the recommended
range by letting the water run sufficiently. With the selector in position 37ºC, the temperature of the water coming
out of the faucet must be within a range of 36ºC and 38ºC, as measured by a thermometer. If the temperature out
of the range, the installer can adjust the setting. Proceed with the setting as follows:
Remove the temperature handle kit.
With the faucet on "cold" normal water flow, slowly turn the temperature selector(always in the same direction) until
water at 37ºC is obtained. If the temperature goes over 37ºC, go back to the “cold” setting and set again.
When the temperature is stabilized, do not turn the cartridge spindle, reinstall the handle kit.
Clean Thermostatic Cartridge
Very hard water can obstruct the filters on thermostatic cartridge and reduce the flow of water. Please clean the
cartridge as follows:
Shut off the water supplies of the faucet and open the flow valve, then proceed to remove the cartridge. The
cartridge is sense part, please be careful.
Make sure the handle is aligned with the number 37 on faceplate before your action. Remove the temperature
handle kit. Remove stem, detent and stop assembly(Fig.1). Removing the thermostatic cartridge cautiously(15).
Clean the thermostatic cartridge by soaking it in warm vinegar.
After cleaning, make sure that the black dot is correctly in line with the black line. Install the “stop assembly” back
on the cartridge, adjusting the stop pin into the notch(Fig.2). Install the cartridge and stop assembly into the body,
adjusting the stop pin into the notch(Fig.3). Reinstall the ring and screw. Reinstall the temperature handle kit and
align the handle to the “37” on the faceplate.
CARE AND MAINTENANCE
Notch
Stop Pin
2
Black Dot
Black Line
4
7
8
9
10
5
6
4
NOTE:
If the hot and cold water supplies are connected inversely,
installer must exchange the position of the hot and cold insert assy.
Ensure the product works properly.
Insert assy(Cold)
Insert assy(Hot)
78023T-4 78024T-4 78023T-4A 78024T-4A
11
12
14
15
16
13