1199702-W2-H
Push the cut end of the chrome
extension tube into the Concealing
Plate then slide the extension tube
over the threaded end of the brazed
pipe and up through the hole until the
concealing plate is secured in the hole
and the concealing plate is flat against
the ceiling.
Note!
If the hole in the ceiling is
oversize use silicone sealant on the
underside of the concealing plate to
retain it.
Screw the deluge head onto the brazed
pipe outlet by hand.
Note!
Use two
suitably sized wrenches to fully tighten
(approximately 1/4 turn).
Connect elbow to digital mixer valve.
Fit an isolating valve between to
enable easy maintenance. (Pipe and
isolating valve not supplied). Lock pipe
to elbow using clip supplied. Follow
manufacturers guidelines for fitting
alternative push-fit connections and
flexible pipework.
Connect brazed pipe in ceiling to
outlet pipe from digital mixing valve
using elbow supplied. Push all parts
together fully.
Do not fit deluge head until after
pipework has been fully flushed through.
Refer to section
“Commissioning”
in
Digital Mixer Valve Installation guide.
Slide the extension tube down to
conceal the brazed pipe.
Cealing
Plate
Threaded
end of pipe
Deluge
Head