Kohler Mira Eco Скачать руководство пользователя страница 6

6

INSTALLATION

RAC Assembly

The RAC assembly is supplied with built-in mixer 
showers only
.

1.

  Before the RAC assembly can be fi tted  you 

must have fi rst installed your built-in shower 
control and have connected the inlet and
 
outlet pipework. Refer to your shower control 
installation and user guide. 

 

Important! 

Make sure that the outlet pipework 

protrudes through a Ø25 mm hole in the wall 
or stud partition by approximately 40 mm.

 

Note!

 For stud partition installations where 

access to the rear of the partition is possible, 
fi t the RAC wallplate over the outlet pipework 
on the inside of the partition.

 

For stud partition installations where access 
to the rear of the wall is not possible, follow 
instructions for solid wall installations, making 
sure that suitable wall fi xings (not supplied) are 
used to secure the wallplate to the outside of 
the stud partition.

40 mm

RAC Wallplate

(shown fi tted for rear 
access stud partitions only)

Outlet Pipe to Fittings

Thermostatic 

Mixing Valve

2.

  Temporarily cap off the outlet pipe, turn on the 

water supplies and check for leaks.

3. 

Determine the fi nished wall position (e.g. tile 
thickness). Turn off the water supply, carefully 
uncap the outlet pipe and cut to length, the 
outlet pipe must protrude through the 

fi nished 

wall surface

 by 21–23 mm.

 

Note!

 Remove any burrs from the pipes before 

proceeding.

4. 

For solid wall installations or stud partition 
installations 

without

 rear access go to 

instruction 9.

 

For stud partition installations with access 
to the rear of the partition continue with 
instruction 5.

5. 

Finish the wall (e.g. tiles).

 

Important! 

Refer to your shower control 

installation and user guide.

 

Caution!

 Make sure that the fi nished  wall 

is within the maximum and minimum limits 
and to an even depth (no greater than 2 mm 
variation).

6. 

Place the RAC backplate over the outlet pipe 
with the arrow pointing up. The screw holes 
should be at 45° to the horizontal.

7. 

Mark the positions of the two RAC backplate 
fi xing holes and drill the two 5.5 mm holes.

 

Caution! 

Make sure that you do not drill into 

pipework in the wall.

8. 

Hold the RAC wallplate in position on the rear 
of the partition, insert the two backplate screws 
and secure the RAC backplate to the wallplate. 
Make sure that the foam seal abuts the fi nished 
wall surface. Go to instruction 17.

RAC Backplate

Backplate 
Screws

Содержание Mira Eco

Страница 1: ...1 These instructions are to be left with the user INSTALLATION USER GUIDE SHOWER FITTINGS MIRA ECO...

Страница 2: ...el of the bath or shower which could lead to contamination from backsiphonage The supplied hose retaining ring should meet the great majority of user requirements for shower installations with flexibl...

Страница 3: ...x Clamp Bracket 1 x Hose Retaining Ring 1 x Applicator 2 x Fixing Screws 2 x Slide Bar End Supports 2 x Slide Bar End Caps or 1 x 1 75m Flexible Hose PACK CONTENTS Tick the appropriate boxes to famil...

Страница 4: ...with the part names and to confirm that all of the parts are included Only supplied with Built In Variable BIV fitting 1 x Wall Plate 2 x Wall Plugs 1 x Olive 2 x Backplate Screws 1 x Backplate Nut 2...

Страница 5: ...fittings There will be an additional pressure loss through the shower control Pressure loss Pressure difference between the inlet and outlet of the fitting The graph below shows the water saving made...

Страница 6: ...for leaks 3 Determine the finished wall position e g tile thickness Turn off the water supply carefully uncap the outlet pipe and cut to length the outlet pipe must protrude through the finished wall...

Страница 7: ...zontal 11 Mark the positions of the two RAC wallplate fixing holes Wallplate RAC Backplate Backplate Screws Arrow 40 11 Remove the assembly from the wall and separate the backplate from the wallplate...

Страница 8: ...the position of the two fixing holes using the centre slot Warning Make sure that there are no buried cables or pipes in the wall before drilling 7 Drill the two 8 mm holes for the fixing screws and...

Страница 9: ...k from the eco setting Water will flow from the outer set of holes 2 Soothe Turn the spray plate anticlockwise until it clicks two clicks from the eco setting Water will flow from the large diameter h...

Страница 10: ...lumbing installations To minimise the effect make sure that the spray plate is clean Cleaning Many household cleaners contain abrasives and chemical substances and should not be used for cleaning plat...

Страница 11: ...6 Adjustable Showerhead White 1668 025 Adjustable Showerhead Chrome 450 10 Slide Bar White 450 28 Slide Bar Chrome 450 13 Adjuster Ring White 450 13 Adjuster Ring Chrome 1668 029 Spray Plate Pack Chro...

Страница 12: ...vely trained to provide every assistance you may need help and advice spare parts or a service visit Spare Parts We maintain an extensive stock of spares and aim to provide support throughout the prod...

Страница 13: ...Showers Power Showers Smart Showers Shower Towers From Top Shower Brands Mira Showers Aqualisa Showers Triton Showers Gainsborough Showers Shower Pumps can upgrade your showering experience even more...

Отзывы: