10
1232447-W2-A
COMMISSIONING
Maximum Temperature Setting
Before using the shower, the maximum temperature must be checked to make sure that it is
at a safe level. It has been preset to a safe showering temperature under ideal conditions at
the factory, appropriate for most systems. However, site conditions and personal preference
may make it necessary to reset this temperature.
Note! Make sure that the hot water temperature is at least 55°C and that there is sufficient
supply.
Caution!
Before testing the mixer, make sure that the hot and cold water is flowing correctly
by exercising the temperature selector knob between the cold and hot stops.
1.
Turn the temperature selector knob anticlockwise until it stops and test that the
temperature of the water from the shower outlet is hot enough.
2.
If not, depress the override button and carefully rotate the knob further. If the water
temperature is still not hot enough complete the following procedure.
3.
Rotate the temperature selector knob back to the override position.
4.
Push in and rotate the concealing cap clockwise to remove. Remove the fixing screw.
5.
Pull off the temperature selector knob without disturbing the stop assembly.
6.
Replace the temperature selector knob so that the lever is the 1 O'clock position.
7.
Rotate the temperature selector knob against the stop, wait for the water to stabilise
and test that the temperature of the water from the shower outlet is hot enough.
If the water temperature is still not hot enough repeat the procedure until a maximum
safe temperature is achieved at the override position.
8.
Refit and tighten the fixing screw, refit the concealing cap.
Fixing Screw
Concealing Cap
Stop Assembly
Temperature
Selector Knob
Push in and
rotate to remove
Bar Valve Commissioning