1017598-2-
A
9
Kohler Co.
Fig. #18
Rite-Temp Handle
Screw
Grip Rings
Cap and Button
Assembly
Seal
4.
Snap cap assembly into place over sleeve. Slide second grip
ring over cap assembly.
H. SECURE TOWER ASSEMBLY:
1.
See Fig. #19 . After handle is installed, secure the four
latches: align 1/8” hex head wrench into latch, push in on
tower, and rotate latch 1/2-turn.
Fig. #19
1/8” Hex Wrench
I. MAKE ELECTRICAL CONNECTION:
1.
Have a licensed electrician connect the transformer leads
from the shower tower power cord and make a routine service
connection to the transformer. See Fig. #20 .
Transformer is not supplied with K-74-JA. Properly
wire a transformer with output voltage of 12 VAC +/– 5% @ 5A.
Fig. #20
Blue
Black
White
Blue
Transformer
12 VAC
18/2 SJO Cord
120 VAC
Earth
Ground
Strain Relief
Not Provided
Strain Relief
Not Provided
To TB1 Connector
Supply Voltage
Black
White
Risk of electrical shock. Disconnect power
before installing or servicing transformer.
2.
Remove the transformer enclosure cover.
3.
Place strain relief bushing on SJO cord from shower tower
assembly. Feed power cord through upper port on the
transformer enclosure. Allow ample cord for connection and
tighten strain relief bushing.
4.
Attach leads as illustrated.
5.
Supply 120 VAC power line with strain relief bushing. (See
Specifications on first page.) Feed incoming power line
through one of the lower knockouts on the transformer
enclosure. Allow ample line for connection and tighten strain
relief bushing.
6.
Attach leads as illustrated.