Maintenance
Inspection and maintenance schedules
Task iden
tification
Component
Schedule
Service
Type
Task description
Time limit (h)
Calendar limit (y
ear)
R
eplacemen
t
Ov
erhaul
Inspection/Clean R
epair
/Adjus
tmen
t
SL106
Recommended:
Fuel pre-filters
1000
2Y
X
Replace primary fuel filter cartridge.
See the operator and maintenance manual of your
application.
SL107 Oil separator filters
7500
2Y
X
Replace oil separator filters.
see: 5.12.2 Replacing crankcase breather — SL107,
SL108 Recommended: Air
f Air ducting
3000
2Y
X
Replace the air filter and clean air ducting between
air filter and compressor.
See the operator and maintenance manual of your
application.
SL109
Alternator belt
1500
2Y
X
X
Inspect conditions of drive belt and fit new one if
necessary.
5.8.1 Removing the battery charging alternator
information see: 5.8.3 Replacing drive belt — SL 109,
SL110
Alternator belt
tensioner
1500
18Y
X
Visual inspection of the tensioner. Replacement if
necessary.
(For more information see: 5.8.4
Replacing tensioning device — SL110, page 109.)
SL116
Cooling system
6000
4Y
X
Replace coolant (at least every 4 years for coolant
formulated with Glysantin G48).
Respect fluids and lubricants specifications.
more information see: 5.14 Lubricants and oper‐
Note: for coolant formulated with Glysantin G40,
the extension up to 8000h/6Y is possible after
analysis.
5.10.2 Replacing coolant — SL116, page 123.)
SL1-53
20
Diesel exhaust
fluid filter
1500
0.5Y X
Replace filter according to time limit or calendar
limit or if required by service tool indication.
more information see: 5.13.1 Replacing diesel
exhaust fluid filter — SL1-5320, page 136.)
SL1-53
10
Diesel exhaust
fluid
-
-
X
Change diesel exhaust fluid at an interval
according to the specification.
SL1-54
61
Engine by-pass
flap
3000
2Y
X
Inspect overall condition including proper func‐
tioning of the flap.
5.12.3 Inspecting engine by-pass flap — SL1-5461
(depending on configuration), page 135.)
Tab. 20: Service level 1 — PRP — Basic maintenance - Version: 2021-07
3)
The warning alarm for filter change will occur at 1300h. Filter must be replaced before 1500h
in order to avoid engine shutdown.
KD62V12 33521030301_8_1 EN_US 2022-09
© 2022 by Kohler Co. All rights reserved.
95
Содержание KD62V12
Страница 6: ...6 2022 by Kohler Co All rights reserved KD62V12 33521030301_8_1 EN_US 2022 09...
Страница 8: ...8 2022 by Kohler Co All rights reserved KD62V12 33521030301_8_1 EN_US 2022 09...
Страница 163: ...Operating faults Faults Cause Remedy KD62V12 33521030301_8_1 EN_US 2022 09 2022 by Kohler Co All rights reserved 163...
Страница 210: ...33521030301_8_1 EN_US 2022 09 LHID12566146 2022 by Kohler Co All rights reserved...