4. Install the Trim - K-T10423
Firmly press the valve stem adapter onto the valve stem.
Secure the valve stem adapter to the valve stem with the correct
length screw, as selected in the
″
Install the Valve Stem Adapter
″
section of this guide.
Align the holes on the front plate assembly and the valve.
NOTE:
Be sure to select the correct length screw for your
application.
Attach the two screws through the front plate assembly and into
the valve. Do not overtighten.
Inspect the front seal plate assembly to ensure that the foam seal
is completely covering the wall opening. If not, stop the
installation and repair the wall opening.
Place the escutcheon against the wall. The drain hole in the
escutcheon should face downward in the 6 o’clock position.
Thread the adapter ring onto the hub of the front plate assembly.
Place the handle assembly against the escutcheon by lining up the
pins in the handle assembly with the holes in the escutcheon.
Make sure the handle is pointing down to the 6 o’clock position
and the setscrew hole is facing down.
Tighten the setscrew in place with a hex wrench. Make sure the
handle assembly is tight against the escutcheon.
Volume Control
Escutcheon
Screw
Screw
Screw
Front Plate Assembly
Adapter Ring
Handle Assembly
Setscrew
Valve Stem Adapter
1041505-2-G
6
Kohler Co.
Содержание K-T10428
Страница 21: ...1041505 2 G ...
Страница 22: ...1041505 2 G ...
Страница 23: ...1041505 2 G ...
Страница 24: ...USA 1 800 4 KOHLER Canada 1 800 964 5590 México 001 877 680 1310 kohler com 2006 Kohler Co 1041505 2 G ...