Troubleshooting (cont.)
Faucet Troubleshooting Table
Symptoms
Probable Causes
Recommended Action
D.
The outlet
hose is
kinked.
D.
Confirm the mounting
bracket and valve box
are located within 10
″
(254 mm) from the
faucet centerline and
within 8
″
(203 mm) to
13
″
(330 mm) above the
cabinet floor.
E.
One or more
screens are
clogged.
E.
Refer to the
″
Cleaning
the Screens
″
section.
F.
Cracked
diaphragm.
F.
Replace the valve box
assembly.
3.
Poor spray
pattern.
A.
The spray
nozzles are
clogged.
A.
Rub your finger over
the nozzles with water
running to dislodge
debris.
4.
Water drip or
trickle when
faucet is not in
use.
A.
Manual
override is
partially
engaged.
A.
Turn the manual
override clockwise until
it stops; then turn it
counterclockwise until
the water drip stops.
Valve Box Troubleshooting Table
Symptoms
Probable Causes
Recommended Action
1.
Water leaking
from the valve
box.
A.
Hose
connections
are not
secure.
A. CAUTION: Risk of
personal injury or
product damage.
Turn
off the main power and
water supply. Check all
connections. Make
adjustments as needed.
B.
Internal leak.
B.
Replace the valve box.
2.
No audible
″
click
″
when the valve is
activated.
A.
Loose valve
box wire
connection.
A.
Check the valve box
wire connection.
B.
Valve is not
functioning.
B.
Replace the valve box.