background image

-2-

1276024-T01-D

Unit: mm

:

Reference Value

Kohler reserves the right to change marked dimensions without prior notice.

482.5

462.2

149.4

Water Supply

Low Pressure Switch

Inlet TDS

TDS

Inlet Solenoid Valve

Drain Solenoid Valve

Drain

Outlet TDS

TDS

High Pressure Switch

Pure Water

Odor-Free Carbon Filter

High Efficacy Reverse Osmosis Filter

RO

Composite Actived Carbon Filter

WATERWAY F

IG

URE

ELECTR

I

CAL D

I

AQRAM

Composite Activated
Carbon Filter

80031T-R1-01R

High Efficacy Reverse
Osmosis Filter

80031T-R2-01R

Odor-Free
Carbon Filter

80031T-R3-01R

Booster Pump

AC/DC

24VDC

220VAC/50HZ

WIFI

Faucet Indicator

Led Bar

High
Pressure
Switch

Low
Pressure
Switch

Booster
Pump

Water-in
Solenoid
Valve

Drain
Solenoid
Valve

Inlet TDS

TDS

Outlet TDS

TDS

Flow Meter

Water Leak Detector

Display

Main Control Circuit Board

Reset
Button 3

3

Reset
Button 2

2

Reset
Button 1

1

Содержание K-80021T-KP040-01R

Страница 1: ...LTD NO 158 JIANG CHANG SAN ROAD JING AN DISTRICT SHANGHAI PRC POST CODE 200436 158 200436 Installation Guide Kitchen Water Filtration System Carafe Series K 80021T KP040 01R K 80021T KP050 01R Copyright Kohler China Investment Co Ltd 2016 2016 ...

Страница 2: ...owtorch or other high temperature sources are nearby The filter must be installed with the inlet outlet and drain ports as labeled Make sure not to reverse connections Water filtration faucet is not supplied with the product you will need to purchase a water filtration faucet with a G1 2 connector or with a 1 4 adapter Note Do not use filtered water for the water exchange of an aquarium or a fishb...

Страница 3: ...is Filter RO Composite Actived Carbon Filter WATERWAY FIGURE ELECTRICAL DIAQRAM Composite Activated Carbon Filter 80031T R1 01R High Efficacy Reverse Osmosis Filter 80031T R2 01R Odor Free Carbon Filter 80031T R3 01R Booster Pump AC DC 24VDC 220VAC 50HZ WIFI Faucet Indicator Led Bar High Pressure Switch Low Pressure Switch Booster Pump Water in Solenoid Valve Drain Solenoid Valve Inlet TDS TDS Out...

Страница 4: ...Chlorine reduction Total product water drain High Efficacy Reverse Osmosis Filter Recommendation about 2 years 2 3 3 Recommendation about 2 years 2 3 3 Odor Free Carbon Filter 800gal Chlorine reduction 700gal Chlorine reduction 1 Production Rating at 40 psi 25 C 250 mg L Nacl solution influent 2 Ratio of Product to Flush Flow may vary with pressure 3 The RO Filter performance varies depending on l...

Страница 5: ...lter Connect Fittings Function is used to connect the water supply valve to the water filtration faucet Filter including Pre filter RO and the Post filter 3 level change this filters matched the button colour NOTE If the system will not be installed immediately refrigerate the RO membrane element at 35 40 F 2 5 C RO 2 5 C 1 4 1 2 Male Adapter BSTP 2 4 BSTP Drain Saddle Clamp Kit Power Adaper Trans...

Страница 6: ...ne from threaded stub on bottom of tap faucet Figure 2 2 Cold Water Supply Valve Cold Water Supply Valve Fig 1 1 Fig 2 2 Stub of Tap Faucet 3 Screw the water supply adapter female threaded stub to the cold water supply valve male threads as shown Hand it tighten and snug with wrench Screw the female threaded tap faucet stub to the water supply adapter Figure 3 3 Fig 3 3 Stub of Tap Faucet Water Su...

Страница 7: ...ucet Signals Only with Matchable Faucet Power Drain Water 1 4 2 Product Water 1 4 2 Raw Inlet 3 8 3 Connections to undersink plumbing can be made with a saddle clamp designed to accept the drain tubing from the RO system Kohler offers a saddle kit PN 1275904 designed for 40mm undersink drain plumbing Figure 13 RO 1275904 40mm Be sure to check and follow local plumbing codes prior to installation C...

Страница 8: ...dge with the hollow icon on the filter base then turn cartridge clockwise until the hollow icon of the cartridge were aligned the color filled icon on the filter base it will be fully installed Figure 9 O 90 9 Rotate 90 degree Pull out the old filter 90 Change new filter matched the button colour Aim at the dot rotate 90 degrees to fix 90 Fig 10 10 When filters replaced remember to push and hold t...

Страница 9: ...water And the indicator light will be waterfall effect Make sure the filtration faucet be turned off Figure 11 1 2 5 11 Note Please confirm supply water inlet pipe drain pipe is already connected the system will automatically start washing and draining before connecting power when the system is brand new 3 When the second stage RO filter or the third stage carbon block filter is brand new replaced...

Страница 10: ... filter indicator will be white the TDS value be displayed TDS Washout When the first stage filter is brand new replaced or the system after every 24 hours working the system will do washout to get it ready for making clean water If power cut during the washout it will continue washout until time over when plug the power again 24 5 15 Filter Status Filter life is running low less than 10 Filter LE...

Страница 11: ...sconnected TDS inlet 03 TDS Display ERR before TDS IN and 03 before TDS OUT when users turn the filtration faucet on it comes with 3 repeating short beeps It means the TDS inlet is not connected Err 03 TDS Error 01 Leaking issue 01 When the leaking issue occurs system will shut down the TDS indicator will display Err 01 on your machine when users turn the filtration faucet on it comes with a repea...

Страница 12: ... normal condition just to discharge a small amount of product water System Alarm is a natural concomitant of this condition if the alarm disappeared after producing the water a minute later system do not need any treatment Before prolonged periods of non use such as during a vacation it is recommended that the cold water supply valve be turned off If it is more than one week please flush the filte...

Страница 13: ...ervice Contact Kohler service Contact Kohler service Change in line pressure Repeat unplug and plug once Contact Kohler service Contact Kohler service Check all fittings tiny leakage or not Change in line pressure or wait for the water pressure change to normal Check the filtration faucet closed tightly or not Replace filter element Plug in again Check and Replace filter Contact Kohler service Con...

Страница 14: ...1276024 T01 D 80021T KP040 01R KP040 80021T KP050 01R KP050 220V 50Hz 70W 1 05L min 3800L 75W 1 31L min 3900L 5 38 0 15 0 4Mpa Q31 0108000050C001 2015 0123 302 303 307 308 ...