background image

-3-

WIRING DIAGRAM

LED POWER

LED

HEATER

THERMOSTAT

THERMAL FUSE

OVER CURRENT FUSE

MOTOR

CAPACITOR

ALL-POLE SWITCH (OPTIONAL)

220V
50Hz

CN4

CN7

CN8

CN5

CN2

CN9

CN13

CN1

CN11

CN12

CN10

TEMPERATURE

AND HUMIDITY

SENSOR MODULE

AIR-CARE MODULE

STEPPER MOTOR

INDICATOR LIGHT

MODULE

THE RATE OF THE

POWER SWITCH

MUST NOT BE LOWER THAN 250V

16A

250V

16A

YELLOW/GREEN

/

RED

BLUE

BLUE

BLUE

BLUE

RED

RED

RED

BLACK

BLACK

WHITE
WHITE

WHITE

WHITE

WHITE

WHITE

BROWN

GRAY

PINK

PINK

YELLOW

YELLOW

YELLOW

ORANGE

ORANGE

MAIN

CONTROL

CIRCUIT

BOARD

+

+

+

+

+

+

There's no risk of damage to the insulation of power cord.
Copper cord must be inserted into the pillar terminal hole, and make
sure all the cords under the terminal are inserted into the pillar
terminal completely.
Suggest using a power cord which with specification 60227 IEC 53
Model's powercord Specified in GB/T 5023.5 and with cross section
of 3X1.0mm .

,

GB/T 5023.5

60227 IEC 53

,

3X1.0mm

2

2

Terminal

Conductor

Insulation

8

(Unit: mm)
(

:

)

WARNING

Make sure the power cord installed firmly,

otherwise it may catch fire.

Conductor

Earth

Power Cord

8

8

13

10

1325978-T01-A

Содержание K-77316T-C-MZ

Страница 1: ...and Homeowners Guide Underscore Bathroom Heater S300 S300 K 77316T C MZ Air care KOHLER CHINA INVESTMENT CO LTD NO 158 JIANG CHANG SAN ROAD JING AN DISTRICT SHANGHAI PRC POST CODE 200436 158 200436 1...

Страница 2: ...e cleaning and warranty information This product complies with GB 4706 1 2005 GB4706 23 2007 and GB 4706 27 2008 please leave instructions for the consumer GB 4706 1 2005 GB4706 23 2007 GB 4706 27 200...

Страница 3: ...2 2m min 3 2 2m min 3 43dB 43dB IPX2 Bathroom Heater IPX2 IPX4 Remote Control IPX4 SIMPLIFIED DIAGRAM OF THE UNIT Note Plaster or other ceiling opening dimension 280 X 285 mm 280 X 285 mm 5 0 5 0 5 0...

Страница 4: ...OWN GRAY PINK PINK YELLOW YELLOW YELLOW ORANGE ORANGE MAIN CONTROL CIRCUIT BOARD There s no risk of damage to the insulation of power cord Copper cord must be inserted into the pillar terminal hole an...

Страница 5: ...Outlet window installation Fix the air exhaust pipe to the outlet window on the wall with the clamp as the preparation of bathroom heater installation Seal the pipe and the outlet window with foaming...

Страница 6: ...1285553 Lock Assy M6 Butterfly Nut M6 6 Washer 6 6Spring Washer 6 M6 Nut M6 Note Initial Length 275mm Stretch Length 1300mm 275mm 1300mm BTP4 8 Triangular Self Tapping Screw BTP4 8 270mm 1285556 Remot...

Страница 7: ...0mm or above The power cord to the product shall have enough length for the installation The distance between the product and the air outlet window shall be 1000mm or lower Cut the screw rod M6 to sui...

Страница 8: ...plate again 2 1 2 3 4 5 6 7 3 3 Installing the Main Body Method 1 integrated ceiling integrated ceiling should be 300 300 300 450 300 600 1 Disassembly the decorated plate around the position of the...

Страница 9: ...by 8 BTP4 8 screw 3 M6 4 8 BTP4 8 M6 Butterfly Nut M6 6 Washer 6 6 Spring Washer 6 M6 Nut M6 M6 Nut M6 BTP4 8 Triangular Self Tapping Screw BTP4 8 8 Suspender Cement Board Ceiling Surface Install temp...

Страница 10: ...t Taper 1 100 1 50 BTP4 8 Triangular Self Tapping Screw BTP4 8 1 80 Ventilation Outlet Assy 80 Ventilation Outlet Assy Clamp Air Exhaust Pipe 80mm 7 Install the decorated plate and adjust the nut on t...

Страница 11: ...ing position of the suspender as shown by the install template 2 Cement Board Suspender 10 2 Fix the ventilation outlet assy to the main body using the BTP4 8 self tapping screw 3 Fix the suspension b...

Страница 12: ...e to install the remote controller shall not be easily splashed by water Choose a mounting location for the remote holder Drilling two holes with depth larger than 45mm on the wall by drill with a dia...

Страница 13: ...mer down UP Timer up HEATER Turn on the heater mode FAN Turn on the fan mode DRY Turn on the hot cool dry clothes mode VENTILATION Turn on the ventilation long time vent mode 24 AIR FLOW Set the air f...

Страница 14: ...ours the setting time cannot be changed E 6 10 6 6 10 6 6 10 6 6 10 6 2 10 2 24 24 TROUBLESHOOTING Problem Diagnosis Solution Bathroom Heater does not work The remote controller does not display The r...

Страница 15: ...Do not use eradicator abrasive powder or oil acid or alkali liquid detergent to clean casing or air louver 3 Never try to put a small screw driver or any other object into the holes of air Louver fro...

Страница 16: ...not easy to be affected by damp 3 The head AC power supply must be protected with appropriate fuse 4 Please confirm the AC power supply should be shut off before maintaining the products with AC powe...

Отзывы: