Troubleshooting (cont.)
Sensor Troubleshooting Table
Symptoms
Probable Causes
Recommended Action
1.
Intermittent sensor
operation.
A.
Debris on the
sensor lens.
A.
Use mild soap and
water to gently remove
debris from the sensor
lens.
B.
Sensor is
detecting
steam.
B.
Rotate the spout away
from the steam.
2.
Handle LED is lit,
but green sensor
LED is not.
A.
Loose sensor
wire
connection.
A.
Check sensor wire
connection to the circuit
board.
B.
Debris on the
sensor wire
connector.
B.
At the circuit board,
gently disconnect,
clean, and reconnect the
sensor wire connector.
C.
Circuit board
is not
functioning.
C.
Replace the cover
assembly.
3.
Yellow sensor LED
does not
illuminate with an
object in front of
it.
A.
Object is
clear or color
is
undetectable
by the sensor.
A.
Test the sensor using
your hand.
B.
Debris on the
sensor wire
connector.
B.
At the circuit board,
gently disconnect,
clean, and reconnect the
sensor wire connector.
Kohler Co.
19
1186051-2-E
Содержание K-72218
Страница 15: ...Kohler Co 1088977 2 H ...
Страница 16: ...1088977 2 H ...
Страница 25: ...Installation Installation Instalación Kohler Co 9 1125005 2 B ...
Страница 30: ...1125005 2 B Kohler Co ...
Страница 31: ...Kohler Co 1125005 2 B ...
Страница 32: ...1125005 2 B ...
Страница 48: ...1130284 2 E ...
Страница 49: ...Installation and Care Guide Electronic Kitchen Faucet K 72218 1186051 2 E ...
Страница 108: ...USA Canada 1 800 4KOHLER México 001 800 456 4537 kohler com 2013 Kohler Co 1186051 2 E ...