Faucet Troubleshooting Table
Symptoms
Probable Causes
Recommended Action
1.
No water flow.
A.
The supply
stops are
closed.
A.
Confirm the supply
stops are open.
B.
Handle is in
the closed
position.
B.
Rotate the handle to the
open position. Refer to
the
″
Faucet Operation
″
section.
C.
The hot
and/or cold
supply hose
is kinked.
C.
Confirm the supply
hoses are not kinked. If
coiled, maintain an
inside diameter of 3
″
(76 mm).
D.
The outlet
hose is
kinked.
D.
Confirm the solenoid
valve is located within
7
″
(178 mm) to 8
″
(203
mm) from the faucet
base.
E.
Handle LED
is not lit.
E.
Refer to the
″
Handle
Switch Troubleshooting
Table.
″
F.
Sensor LED
is not lit.
F.
Refer to the
″
Sensor
Troubleshooting Table.
″
G.
One or more
screens are
clogged.
G.
Refer to the
″
Cleaning
the Screens
″
section.
2.
Low water flow.
A.
The supply
stops are
partially
closed.
A.
Confirm the supply
stops are fully open.
B.
Handle is
partially
closed.
B.
Rotate the handle to the
full open position.
1186051-2-E
16
Kohler Co.
Содержание K-72218
Страница 15: ...Kohler Co 1088977 2 H ...
Страница 16: ...1088977 2 H ...
Страница 25: ...Installation Installation Instalación Kohler Co 9 1125005 2 B ...
Страница 30: ...1125005 2 B Kohler Co ...
Страница 31: ...Kohler Co 1125005 2 B ...
Страница 32: ...1125005 2 B ...
Страница 48: ...1130284 2 E ...
Страница 49: ...Installation and Care Guide Electronic Kitchen Faucet K 72218 1186051 2 E ...
Страница 108: ...USA Canada 1 800 4KOHLER México 001 800 456 4537 kohler com 2013 Kohler Co 1186051 2 E ...