Integral Supply Stop Operation
NOTE:
Use a 3/8
″
square drive or 10 mm hex wrench to adjust the
stops.
Turn Off the Stops
Use a 3/8
″
square drive or 10 mm hex wrench to turn the integral
stops 90° counterclockwise to shut off both the hot and cold water
inlet supplies.
NOTE:
If the integral stop turns, but the outer ring does not turn,
firmly tighten (clockwise) the integral stop. Then rotate
counterclockwise. The outer ring should then turn with the integral
stop.
Confirm the stops are closed using the diagram above.
Turn the flow control counterclockwise to release excess water.
The cartridge may now be removed for servicing or replacement.
NOTE:
Keep a rag handy to catch excess water that will gradually
drain when valve cartridge is removed.
Off
On
Integral Stop
Integral Stop
1066046-5-B
4
Kohler Co.
Содержание K-697