Roughing-In
NOTE:
Use the dimensions in the diagram above for reference when determining the placement and
clearance for the steam generator.
NOTE:
Unions are supplied for the steam outlet and water inlet for connection to 1/2
″
copper pipe.
19-1/8" (486 mm)
1/2" NPT
Steam Outlet
3/8" NPT
Water Inlet
8-3/8"
(213 mm)
3/4" NPT Pressure Relief
Field Wiring
Service Box
10-1/8"
(257 mm)
14-1/4"
(362 mm)
Green LED
Diagnostic Light
Minimum required access panel is
24" (610 mm) L x 15" (381 mm) H.
Allow for a minimum of 12" (305 mm) of
space around all sides of the steam
generator.
Allow for the drain/spill pan.
KOHLER
®
drain pan sold separately.
3/8" NPT
Drain
Control
Cable Input
2"
(51 mm)
Min
2-1/16"
(52 mm)
3/4" NPT
Drain Pan Outlet
5/8" (16 mm)
1"
(25 mm)
8-1/8"
(206 mm)
11-1/4"
(286 mm)
3/4"
(19 mm)
2-1/8"
(54 mm)
1-7/8"
(48 mm)
3-5/16"
(84 mm)
1-5/16"
(33 mm)
6" (152 mm)
2-1/8"
(54 mm)
6-1/8"
(156 mm)
17-5/8" (448 mm)
Kohler Co.
5
1230487-2-E
Содержание K-5525-NA
Страница 49: ...1230487 2 E ...
Страница 50: ...1230487 2 E ...
Страница 51: ...1230487 2 E ...
Страница 52: ...USA Canada 1 800 4KOHLER México 001 800 456 4537 kohler com 2018 Kohler Co 1230487 2 E ...