1302892-T01-
B
56
Kohler Co.
Click remote UV button to perform UV sterilization function when toilet cover is CLOSE. This process is about 34
min. During UV sterilization process, UV sterilization function will be deactivated if customer opens cover and
seated on toilet, or press STOP button on side panel.
。
Press dryer button to activate dryer function
Light induction zone
Press night light function down (long beep indication)
Press again to activate night light function (short beep
indication).
Press to enter rear wash
STOP function
Press to flush the toilet
Note
:
1.Each function shall perform ex-work setting. Customer shall be able to change setting by remote (review remote setting
guide).
2.
Press STOP button during front wash or rear wash to deactivate the function; otherwise turn off this function automatically after 5 min.
3. Press STOP button during dryer operation to deactivate this function; otherwise turn off this function automatically after 4
min.
UV Sterilization Function
*
Side Panel Function
UV sterilization function is used to sterilize wand by UV.
Auto UV sterilization
E-water Function
*
E-water function is to sterilize nozzle by e-water.
Toilet shall activate E-water sterilization function after customer complete front wash, rear wash or spiral wash etc.
function and unseated.
Auto activate E-water sterilization function every 8 hrs when nobody seated on toilet.
Auto activates UV sterilization function to sterilize wand if nobody use for a long time. The process is about 45
min. This function will not be reactivated within next 24 hrs.
During UV sterilization process, UV sterilization function will be deactivated if customer opens cover and seated
on toilet, or press STOP button on side panel.
Auto UV sterilization function setting refers to Page
51
.
Manual UV sterilization
Press to enter front wash
*
UV sterilization (refers to the ultraviolet sterilization generated by UV lamp): during UV working period, eliminate bacteria, reduce bacteria growth on nozzle surface, this does not
represent the mildew and other incidental effects. The antibacterial rate is more than 99% (measured after an UV work cycle).
Sterilized water (refers to refers to the tap water containing hypochlorite generated by chlorine ions after ionization): wash nozzle surface by sterilized water generated within
working cycle, reduce bacteria growth on nozzle surface, and represent the mildew and other incidental effects. The antibacterial rate is more than 99% (Perform tester per G/T
5750.12-2006, the content of chlorine ions in tap water is >24ppm, different water quality might cause different sterilization effect).
*