Clean the Inlet Screens
Disconnect the power and turn off the water supply.
Unthread the plastic nuts from the hot and cold inlets.
Remove the copper tubes. The O-ring and screen may be attached to the end of the tube.
If the screen remains in the check valve, use a small flat-blade screwdriver to gently pull the check
valve from the valve inlets.
Remove the screens from the copper tubes or check valves.
Clean the screens to remove any dirt or debris.
Rinse or replace the check valves and screens.
Reassemble the inlet connections.
Screen
Nut
Copper Tube
Check Valve
Seal
O-Ring
Boot
Split Boot
1143086-5-E
8
Kohler Co.