![Kohler K-29709 Скачать руководство пользователя страница 14](http://html1.mh-extra.com/html/kohler/k-29709/k-29709_installation-and-care-manual_1987992014.webp)
3. Reverse the Inlet Supplies
IMPORTANT! The steps in this section are optional.
Only perform
these steps when the hot and cold inlet supplies are reversed.
The inlet connections are indicated on the inlet ports of the
thermostatic valve assembly. Left is HOT and right is COLD. If this
configuration is not suitable for your installation, the cartridge may
be rotated 180° to reverse the hot and cold inlet ports.
NOTE:
DO NOT pull the removal clip from the cartridge assembly
at any time during this procedure. The retaining clip helps hold the
temperature limit stop and detent components in place and reduces
or eliminates the need for temperature adjustments.
With the valve already installed and pressurized:
Turn both integral supply stops 90° counterclockwise until they
contact the stop bracket.
Turn the volume control valve stem (not shown) fully clockwise
to release the pressure.
Slowly loosen the head nut, turning it counterclockwise. This will
begin to draw the cartridge out of the valve body.
Cartridge
Remove the cartridge and rotate 180˚.
Seal
Seal
Head Nut
Supply Stops
Tab
1205551-2-D
14
Kohler Co.
Содержание K-29709
Страница 46: ...Entretien des filtres cont R installer la garniture 1205551 2 D Fran ais 19 Kohler Co...
Страница 86: ...1205551 2 D...
Страница 87: ...1205551 2 D...
Страница 88: ...USA Canada 1 800 4KOHLER M xico 001 800 456 4537 kohler com 2018 Kohler Co 1205551 2 D...