4. Install the Steam Adapter - Single Steam Head Configuration
Remove the adhesive backing from the back of the steam adapter.
Mount the steam adapter firmly to the side panel of the steam generator.
NOTICE:
Do not pinch, nail, wedge, or use undue force when handling the silver crossover connector
cable. Any damage may result in adapter kit failure. If the steam adapter kit is not installed immediately,
protect the control cable end with tape or other shielding material.
Carefully plug the silver crossover cable into the steam adapter and the steam generator.
Connect the temperature sensor wire to the corresponding port on the steam adapter.
Route the media module cable from the steam adapter to the media module (or peripheral
equipment) and connect at both ends. Refer to and follow the instructions packed with those
devices.
The terminator is factory installed and must remain installed if no additional equipment is to be
added in series to this device. If additional equipment is to be connected downstream of this device,
remove the terminator and follow the instructions packed with the additional equipment.
Turn on the water supply.
Restore the power at the main breaker panel.
Turn on the power to the generator.
Steamhead and
Housing Assembly
DTV II Media
Module
DTV-II
Drain Pan
Steam Adapter Kit
Harness, CSM Peripheral
Steam Generator Control Cable Input
(location varies by model)
Temperature Sensor
Cable Data, 10" (25.4 cm) Silver,
Crossover
1069332-2-C
8
Kohler Co.