background image

Product Information

Whirlpool with chromatherapy

lights

K-1394-H2

not

shown

Whirlpool w/o chromatherapy

lights

K-1394-H3

shown

Required accessories:
Jet trim kit

K-9398

Fixture:*

basin area

top area

weight

Bathing

well

54-1/2

(138.4 cm)

x 44

(111.8 cm)

61-5/8

(156.5 cm)

x

54-1/2

(138.4 cm)

260 lbs.

(118 kg)

water depth

capacity

To

overflow

19

(48.3 cm)

196 gal. (742 L)

* Approximate measurements for comparison only.

Pump: (Qty. 2)

Hp

Voltage

Frequency

Amps

Variable speed

2 hp

240 V

50/60 Hz

18 A

Cut-out template

1006705-7

Required Electrical Service (2 required)

Two dedicated circuits required, each protected with a Class A

Ground-Fault Circuit-Interrupter (GFCI) or Earth-Leakage

Circuit-Breaker (ELCB):
Pump/control

220-240 V, 20 A, 50/60 Hz

Heater

220-240 V, 20 A, 50/60 Hz

Installation Notes

NOTE:

Pump protrusion beyond rim.

Install this product according to the installation guide.
Two separate 240 V electrical services required; one for the

pump/control, and another for the heater.
Floor support under whirlpool must provide for a minimum of

2500 lbs. (1134 kg).
Hot water supply should be 70% of capacity or greater.

Installations will vary.

2" O.D.

3" (7.6 cm)

3-1/2" (8.9 cm)

9/16" (1.4 cm)

2-3/4" (7 cm)

21-1/8" (53.7 cm)

66" D. (167.6 cm)

2-1/2" (6.4 cm)

3-1/2" (8.9 cm)

26-5/16" 
(66.8 cm)

14-7/16" 
(36.7 cm)

11-5/16" 
(28.7 cm)

25" 
(63.5 cm)

23-1/2" 
(59.7 cm)

Note: Pump Protrusion Beyond Rim

Pump/Control Access

No change in measurements with drain 
shown. (K-7167 or K-7167M)

48" (121.9 cm) W x
18" (45.7 cm) H Min.

K-1394-H3

Drop-in cut-out 64-1/2" D. (163.8 cm)

1022209-1-C

2

Kohler Co.

Содержание K-1394 Series

Страница 1: ...bers are for Mexico i e K 12345M Los números de productos seguidos de M corresponden a México Ej K 12345M Français page 3 Español página 4 USA 1 800 4 KOHLER Canada 1 800 964 5590 México 001 877 680 1310 kohler com K 1394 1022209 1 C 2004 Kohler Co ...

Страница 2: ...Leakage Circuit Breaker ELCB Pump control 220 240 V 20 A 50 60 Hz Heater 220 240 V 20 A 50 60 Hz Installation Notes NOTE Pump protrusion beyond rim Install this product according to the installation guide Two separate 240 V electrical services required one for the pump control and another for the heater Floor support under whirlpool must provide for a minimum of 2500 lbs 1134 kg Hot water supply s...

Страница 3: ...sjoncteur détecteur de fuite à la terre ELCB Commande de pompe 220 240 V 20 A 50 60 Hz Chauffage 220 240 V 20 A 50 60 Hz Notes pour l Installation REMARQUE Pompe dépassant du bord Installez ce produit selon la notice d installation Deux circuits électriques séparés de 240 V sont nécessaires un pour la pompe la commande et l autre pour le chauffage Le sol sous la baignoire à hydromassage doit pouvo...

Страница 4: ...iente de pérdida a tierra GFCI de clase A Bomba control 220 240 V 20 A 50 60 Hz Calentador 220 240 V 20 A 50 60 Hz Notas para la instalación NOTA La bomba sobresale del reborde Instale este producto conforme a la guía de instalación Requiere dos circuitos eléctricos separados de 240 V uno para la bomba control y el otro para el calentador El soporte del piso debajo de la bañera de hidromasaje debe...

Отзывы: