Troubleshooting Procedures (cont.)
Symptoms
Probable Causes
Recommended Action
C.
Motor/pump does not work.
C.
Replace motor/pump. Refer to the
installer/dealer.
D.
Control does not work.
D.
Replace control. Refer to the
installer/dealer.
7.
Little or poor water flow
from dual fill ports (if
included).
A.
Water supply lines blocked
A.
Remove blockage.
B.
Transfer valve not fully open.
B.
Rotate transfer valve handle.
8.
Little or poor water flow
from Waterfall.
A.
Suction or harness blocked.
A.
Remove blockage.
B.
Pump does not work.
B.
Replace pump. Refer to the
installer/dealer.
C.
Control does not work.
C.
Replace control. Refer to the
installer/dealer.
9.
Flexjets operate, but
Riverjets do not operate
as described.
A.
Insufficient water in whirlpool
basin.
A.
Fill whirlpool so water covers
water-level sensors.
B.
User keypad does not work.
B.
Replace user keypad. Refer to the
installer/dealer.
C.
Butterfly valve does not work.
C.
Check wiring. Replace butterfly
valve. Refer to the installer/dealer.
D.
Control does not work.
D.
Replace control. Refer to the
installer/dealer.
10.
Up/down volume control
arrows do not change
water flow as described.
A.
User keypad does not work.
A.
Check wiring. Replace user keypad.
Refer to the installer/dealer.
B.
Pump does not work.
B.
Replace pump. Refer to the
installer/dealer.
C.
Control does not work.
C.
Replace control. Refer to the
installer/dealer.
11.
Air flow through jets does
not stop when Tidepool
mode is activated.
A.
User keypad does not work.
A.
Check wiring. Replace user keypad.
Refer to the installer/dealer.
B.
Butterfly valve does not work.
B.
Check wiring. Replace butterfly
valve. Refer to the installer/dealer.
C.
Control does not work.
C.
Replace control. Refer to the
installer/dealer.
12.
Air continues to flow
through one or more jets
for several seconds after
Tidepool mode is
activated.
A.
Normal operation - air will stop
flowing in a short time.
A.
No action required.
13.
Pump stops before 18
minutes.
A.
GFCI or RCD tripped.
A.
Identify source of fault, and correct.
Reset GFCI or RCD.
B.
Suction is blocked.
B.
Remove obstruction.
C.
Jets are blocked.
C.
Remove blockage.
D.
Motor overheated and
protection device activated.
D.
Check for blockage at suction
and/or jets. Remove blockage and
allow motor to cool.
14.
Pump does not
automatically stop after 22
minutes.
A.
20-minute timer inadvertently
disabled.
A.
See Service Manual.
15.
Pump will not turn off
when the power button
on user keypad is
pressed.
A.
User keypad does not work.
A.
Replace user keypad. Refer to the
installer/dealer.