Product Information

Drop-in bath whirlpool

K-1246

shown

Fixture*:

basin area

top area

weight

Bathing

well

44

(111.8 cm) x

31

(78.7 cm)

50

(127 cm) x

34

(86.4 cm)

110 lbs

(49.9 kg)

water depth

capacity

To

overflow

15

(38.1 cm)

69 gal (261.2 L)

* Approximate measurements for comparison only.

Pump:

Hp

V

Hz

A

1-speed

1.25

120

60

7.5

Included Component:
Cutout template

113926-7

Required Electrical Service

Dedicated circuit required, protected with a Class A

Ground-Fault Circuit-Interrupter (GFCI):
Pump/control

120 V, 15 A, 60 Hz

Locate the outlet behind the whirlpool and within 24

(61 cm)

of the pump.

Notes

Install this product according to the installation guide.
Floor support under the whirlpool must provide for a minimum of

1200 lbs (544.3 kg) loading.
If installing a rim-mount faucet, make sure there is no interference

with the drain overflow and circulating system before drilling any

holes. Consult local and national codes for minimum air gap

requirements if installing a spout on the faucet deck.
Pump must be relocated to custom position at the time of

installation. Provide adequate clearance.
This fixture conforms to ANSI Standard Z124.1. All dimensions are

nominal.
This fixture conforms to CSA B45 and ANSI Standard Z124.1. All

dimensions are nominal.

17"

   

(43.2 cm)

21"

   

(53.3 cm)

16-1/16"

   

(40.8 cm)

3-1/2"

   

(8.9 cm)

1-1/2"

   

(3.8 cm)

12-5/16" (31.3 cm)

5-3/8" (13.7 cm)

2-7/8" (7.3 cm)

60" (152.4 cm)

1-3/16" (3 cm)

3" (7.6 cm)

42" (106.7 cm)

1-1/2" OD

Drop-In Rim Detail

Pump/Control Access 
20" (50.8 cm) W x  
15" (38.1 cm) H Min 
(Typical)

Recommended faucet area.

No change in measurements with drain 
shown. (K-7161-AF or K-7161M-AF)

1013768-1-B

2

Kohler Co.

Содержание K-1246

Страница 1: ...bers are for Mexico i e K 12345M Los números de productos seguidos de M corresponden a México Ej K 12345M Français page 3 Español página 4 USA 1 800 4 KOHLER Canada 1 800 964 5590 México 001 877 680 1310 kohler com K 1246 1013768 1 B 2005 Kohler Co ...

Страница 2: ...inimum of 1200 lbs 544 3 kg loading If installing a rim mount faucet make sure there is no interference with the drain overflow and circulating system before drilling any holes Consult local and national codes for minimum air gap requirements if installing a spout on the faucet deck Pump must be relocated to custom position at the time of installation Provide adequate clearance This fixture confor...

Страница 3: ...nimale de 1200 lbs 544 3 kg Si un robinet sur rebord est installé s assurer qu il n y ait pas d interférence avec le trop plein du drain et le système de circulation avant de percer les trous Consulter les codes nationaux et locaux pour les exigences d espace d air minimum lors de l installation d un bec sur le comptoir du robinet La pompe doit être relocalisée à l emplacement personnalisé au mome...

Страница 4: ...1200 lbs 544 3 kg En caso de instalar la grifería en el borde asegúrese de que no interfiera con el rebosadero de desagüe y el sistema de circulación antes de taladrar los orificios Consulte los códigos locales y nacionales para obtener los requisitos mínimos de espacio libre en caso de instalar un surtidor en la superficie plana para la grifería Durante la instalación es necesario cambiar el luga...

Отзывы: