When unseated, auto starts deodorizer function.
Wide oscillate clean function
Standby
mode
Automatic energy saving function
Deodorizer
The toilet is equipped with wide oscillate clean function. If you would like to use wide oscillate function, long press
Rear Wash + STOP button about 2s after starting Rear Wash + oscillate function.
1.
2. When press any button on side panel or seated, auto exit standby mode, all function recovered.
2. Auto UV sterilization
3.
UV sterilization function*
1. UV function is used to sterilize the nozzle by UV.
When toilet is not in use for a long time, auto UV sterilization function will start and begin to sterilize nozzle.
No sterilization function shall be activated after this process in another 24hrs.
During UV sterilization process, if customer open cover and start use toilet, or presses STOP button on
remote, UV sterilization function will be stopped.
Auto UV sterilization function setting refer on Page
10
.
Long press “ ” button (over 2s) on side panel to start standby mode when the toilet generate one “beep”.
Auto detection and remote function stops at this point, so as IOT function (with IOT function). Seat heating
function stops to minimize energy consumption.
Manual UV sterilization
When unseated, press “Intelligent sterilization” button on remote to start UV sterilization function (details
are shown in the diagram of remote control).
During sterilization process, if customer open cover and start use toilet, or presses STOP button on remote,
UV sterilization function will stop.
When energy saving set to ON status, product shall auto detect the idle hours and decrease the heating
temperature to reach of energy saving purpose.
For details of automatic energy saving, refer to pages
9
.
*
UV sterilization (refers to the ultraviolet sterilization generated by UV lamp):
During UV working cycle, the bacteria on nozzle surface will be eliminated by irradiation. The antibacterial
rate is more than 99%. (Measured after one UV working cycle, it was measured within 1
6
mm×8mm irradiation area. Perform test in accordance with GB /T 23131 requirements, UV
radiation zone was shown in the diagram, UV working cycle activation mode refers to users guide. Testing lab: China household electrical appliances testing institute.)
1408701-TW01-
B
16