background image

12

115982-2-

BA

 (-)

Kohler Co., Kohler, WI

 8. ELECTRICAL CONNECTIONS

A.  IDENTIFY ELECTRICAL REQUIREMENTS

The model number is printed on a label at the pump end
of the whirlpool.

The label identifies electrical rating.

B. WIRING INFORMATION – 120 V, 60 HZ –

2-SPEED PUMP (UL LISTED) MODELS

WARNING: Risk of electrical shock. To reduce
the risk of electric shock, connect only to a properly
grounded, grounding-type receptacle, protected
by a Ground-Fault Circuit-Interrupter (GFCI). Do
not remove the plug’s grounding pin. Do not use a
grounding adapter.

Your Kohler whirlpool bath is equipped with a cord and
plug. All wiring of the pump and control has been
completed at the factory. A licensed electrician must
install a GFCI-protected, 120 V, 20 A, grounded outlet.
Your whirlpool may then be plugged into this outlet. No
other load should be on this circuit. Locate the outlet
behind the whirlpool, and within 24” of the pump.

* For bonding in accordance with national and local
codes.

Switch

Wire

Bonding
(Earthing) Lug*

Pump

Plug-in
Cord

20 A
Receptacle

Control Box

 9. WATER TEST WHIRLPOOL AND ELECTRONICS

Check all electrical connections.

Make sure all pipe connections to the pump are securely
tightened.

Fill the whirlpool to a level at least 2” above the top of the
highest jet.

Operate the whirlpool for 5 minutes, and check all
whirlpool harness (piping) connections for leaks.

For additional information on whirlpool operation, see
Start-Up Whirlpool instructions on Page 14.

Содержание Freewill K-12105-H

Страница 1: ...Freewill Barrier Free Bath Whirlpools K 12105 H K 12106 H 115982 2 BA 1999 Kohler Co...

Страница 2: ...her electrical equipment and exposed metal in the vicinity as needed to comply with local requirements DANGER RISK OF INJURY Hot whirlpool baths can put certain stresses on the body as do any hot bath...

Страница 3: ...Information 120 V 60 Hz 12 WATER TEST WHIRLPOOL ELECTRONICS 12 COMPLETE FINISH WALL 13 COMPLETE INSTALLATION 13 Install Whirlpool Trim Kit 13 Install Faucet And Drain Trim 13 Install Grab Bars 13 Inst...

Страница 4: ...n Outlet 2 1 4 D Approximate measurements for comparison only Pump high HP low HP V Hz A 2 speed 1 1 8 120 60 16 5 D INSTALLATION NOTES Read the entire installation instruction before beginning the in...

Страница 5: ...on 3 PRODUCT REQUIREMENTS A SUMMARY OF KEY REQUIREMENTS Install unit to a level subfloor Provide properly dimensioned framing Recess installation is recommended B PLUMBING SPECIFICATIONS Confirm adequ...

Страница 6: ...our new acrylic module is too large to fit through a standard door opening The unit must be placed within the installation area prior to completion of framing An optional procedure is to omit studs in...

Страница 7: ...vide this clear floor space with either a front or side user access 2 Consider the path of the wheelchair user when building the clear floor space Be sure there is sufficient room for a wheelchair use...

Страница 8: ...truction multiple unit installations At least one unit should have access through which the other unit may be accessed 4 In masonry or fire rated partitions Provide access to plumbing connections 5 Un...

Страница 9: ...plate around the recess opening 2 If extra grab bars are specified Provide 2x6 bridging or attachment at specified positions Refer to the grab bar manufacturer s instructions NOTE A 5 diameter opening...

Страница 10: ...the unit 3 Use a hole saw to drill the holes required Drill from the finished face of the unit CAUTION Risk of product damage When moving the unit do not flex or damage may occur 4 Clean the bath rece...

Страница 11: ...etween the pump base and the subfloor but only high enough to allow water to drain out the suction line when the bath is drained NOTE Do not raise the pump higher than it was before you cut the bandin...

Страница 12: ...ol has been completed at the factory A licensed electrician must install a GFCI protected 120 V 20 A grounded outlet Your whirlpool may then be plugged into this outlet No other load should be on this...

Страница 13: ...sistant Wall Material 11 COMPLETE INSTALLATION A INSTALL WHIRLPOOL TRIM KIT Refer to the installation instructions packed with the trim kit when installing the jet or suction trim B INSTALL FAUCET AND...

Страница 14: ...12 CLEAN UP AFTER INSTALLATION When cleaning up after installation do not use abrasive cleansers as they may scratch and dull the bath surface Use warm water and a liquid detergent to clean the surfa...

Страница 15: ...ng counterclockwise To reduce air and water rotate it clockwise Shut off whirlpool Restart whirlpool after 20 minute cycle is complete Up More Down Less 14 TROUBLESHOOTING PROCEDURES A FLEXJET INSTALL...

Страница 16: ...kit installed incorrectly B Reinstall trim kit checking for damage to O ring 3 Whirlpool stops automatically A GFCI trips A Identify source of fault and correct automatically before 18 minutes B Suct...

Отзывы: