background image

Mounting hole distance: 847 mm

1

2

3 8 7

6

5

4

11

9 (Optional)

14

15

17

16

10

12

13

1

2

3

11

18

CLEANING INSTRUCTIONS

INSTALLATION CHECKOUT

Page 3

1398217-A02-A    16/07/2019

Englefield

INSTALLATION INSTRUCTIONS

STUDIO  

Dual Rain Shower 

Page 2

1398217-A02-A    16/07/2019

Englefield

INSTALLATION INSTRUCTIONS

STUDIO  

Dual Rain Shower 

How to Install the Shower Column & Elbow

INSTALLATION

1. Select a location on a vertical wall to install shower column 

according to rough-in dimensions.

Note: The column must be fixed to timber studs or 

nogs in the wall.

2. Mark the position of top & bottom wall fixing holes on the 

wall (

Distance: 847mm apart

) and then drill a hole at both 

positions.

Note: Minimum 350mm clearance from ceiling to top 

mounting position.

3. Fix mounting brackets (1) to the wall with screw set (2 & 3). 

Align slot in the top mounting bracket horizontally and 

bottom mounting bracket vertically.

4. 

OPTIONAL FOR RETRO-FIT:

 Insert support (9) onto the 

lower tube (5) if required to cover undesired mounting hole 

from a previous installation. Install its mounting bracket 

(18) to the wall accordingly.

4. Slide the clamp bracket (4) onto the lower tube (5) and 

adjust it to the centre of the lower tuble.

5. Screw the lower tube (5) into top tube (6) through top 

support (7) and tighten with screw (8) inside of the top 

support. Connect diverter (10) to shower column.

6. Attach the shower column to the mounting brackets (1) and 

tighten grub screws (11) to hold in place.

7. Fit O-ring (12) into groove in the base of elbow (13) and 

then screw it to G1/2”B water supply nipple (not supplied) 

until the back surface of the elbow touches the finished 

wall. Ensure the outlet of the elbow faces down.

8. Connect water supply hose (600mm length) (14) to FRONT 

INLET of the diverter and to the elbow (13).

9. Connect hand shower hose (1500mm length) (15) to BACK 

OUTLET of the diverter and to hand shower (16).

10. Attach overhead shower (17) to the top tube.

NB: The shower can be operated in two modes, i.e. Hand Shower or Overhead Shower mode.

1. Ensure that all connections are tight.

2. Turn on the main water supply and check for leaks. Repair as needed.

3. Switch the diverter to Hand Shower mode.

4. Disconnect the hand shower from the shower hose and then turn on the shower mixer for mininum one 

minute to flush any residual debris from the lines.

5. Check and clean filter washers as necessary. Reinstall the shower hose back to the hand shower and the 

elbow.

6. Adjust the height of hand shower by sliding the clamp bracket up or down. 

7. Switch the diverter to Overhead Shower mode.

8. Disconnect the overhead shower from the top tube and then turn on the shower mixer for minimum one 

minute to flush any residual defris from the lines.

9. Check and clean filter washers as necessary. Reinstall the overhead shower back to the top tube.

Clean all finishes with mild soap and warm water. Wipe entire surface completely dry with a clean soft cloth. 

Many cleaners may contain such chemicals as ammonia, chlorine, toilet chemials etc, which could adversely 

affect the finish and are not recommended for cleaning. 

Do not use abrasive cleaners or solvents on Englefield fittings.