Air Cleaner
NOTE: Operating engine with loose or
damaged air cleaner components
could cause premature wear and
failure. Replace all bent or damaged
components.
NOTE: Paper element cannot be blown out
with compressed air.
Low-Profi le
Loosen knob and remove air cleaner cover.
Precleaner:
1. Remove precleaner from paper element.
2. Replace or wash precleaner in warm water
with detergent. Rinse and allow to air dry.
3. Saturate precleaner with new engine oil;
squeeze out excess oil.
4. Reinstall precleaner over paper element.
Paper Element:
1. Clean area around element. Remove wing
nut, element cover, and paper element with
precleaner.
2. Separate precleaner from element; service
precleaner and replace paper element.
3. Check condition of rubber seal and replace if
necessary.
4. Install new paper element on base; install
precleaner over paper element; reinstall
element cover and secure with wing nut.
Reinstall air cleaner cover and secure with
knob.
Heavy-Duty
1. Unhook retaining clips and remove end
cap(s).
2. Check and clean inlet screen (if equipped).
3. Pull air cleaner element out of housing and
replace. Check condition of inner element;
replace when dirty.
4. Check all parts for wear, cracks, or damage,
and that ejector area is clean.
5. Install new element(s).
6. Reinstall end cap(s) with dust ejector valve/
screen down; secure with retaining clips.
Breather Tube (if equipped)
Ensure end of breather tube is properly
connected.
Oil Cooler (if equipped)
1. Clean fi ns with a brush or compressed air.
2. Remove two screws securing oil cooler, and
tilt to clean back side.
3. Reinstall oil cooler.
Air Cooling
WARNING
Hot Parts can cause severe
burns.
Do not touch engine while
operating or just after stopping.
Never operate engine with heat shields or
guards removed.
Proper cooling is essential. To prevent over
heating, clean screens, cooling fi ns, and other
external surfaces of engine. Avoid spraying
water at wiring harness or any electrical
components. See Maintenance Schedule.
Repairs/Service Parts
We recommend that you use a Kohler
authorized dealer for all maintenance, service,
and engine parts. To fi nd a Kohler authorized
dealer visit KohlerEngines.com or call 1-800-
544-2444 (U.S. and Canada).
Leakage Check/Testing
With fuel valve fully opened, engine not
running, turn key switch ON. Check all fuel
system connections and lines for leaks using
soapy water. Any leakage must be corrected
before restarting engine. Have service
performed by a Kohler authorized dealer or
qualifi ed propane personnel only.
Storage
If engine will be out of service for 2 months or
more follow procedure below.
1. Change oil while engine is still warm from
operation. Remove spark plug(s) and pour
about 1 oz. of engine oil into cylinder(s).
Replace spark plug(s) and crank engine
slowly to distribute oil.
2. Disconnect negative (-) battery cable.
3. Separate propane tank from unit and store
separately in an area designated for safe
propane tank storage.
4. Store engine in a clean, dry place.