background image

6

Operating Instructions

Also read the operating instructions of the equipment this engine powers.

Pre-Start Checklist

• Check oil level. Add oil if low. Do not overfill.

• Check fuel level. Add fuel if low.

• Check cooling air intake areas and external

surfaces of engine. Make sure they are clean and

unobstructed.

• Check that the air cleaner components and all

shrouds, equipment covers, and guards are in

place and securely fastened.

• Check that any clutches or transmissions are

disengaged or placed in neutral.

WARNING: Lethal Exhaust Gases!

Engine exhaust gases contain poisonous carbon

monoxide. Carbon monoxide is odorless, colorless,

and can cause death if inhaled. Avoid inhaling exhaust

fumes, and never run the engine in a closed building or

confined area.

Cold Weather Starting Hints

1. Be sure to use the proper oil for the temperature

expected. See Figure 2 on page 4.

2. Declutch all possible external loads.

3. A warm battery has much more starting capacity

than a cold battery.

4. Use fresh winter grade fuel. NOTE: Winter grade

gasoline has higher volatility to improve starting.

Do not use gasoline left over from summer.

Figure 6. Location of Choke Lever.

Starting

1. Open fuel shut-off valve.

2.

For a Cold Engine – 

Place the throttle control

midway

 between the 

“slow”

 and 

“fast”

positions. See Figure 5. Place the choke control

into the 

“on”

 position. See Figure 6.

For a Warm Engine (normal operating

temperatures) –

 Place the throttle/choke control

midway

 between the 

“slow”

 and 

“fast”

positions. Place the choke control in the 

“on”

position. See Figure 6.

3. Place start-stop switch in the 

“start”

 position if so

equipped. See Figure 5.

4. Start the engine as follows:

For Retractable Start Engine –

 SLOWLY pull the

starter handle until just past compression – STOP!

Return starter handle, pull firmly with a smooth,

steady motion to start. Pull the handle straight out

to avoid excessive rope wear from the starter rope

guide.

Extend the starting rope periodically and check its

condition. If the rope is frayed, have it replaced

immediately by your Kohler Engine Service

Dealer.

WARNING: Accidental Starts!

Before extending and checking retractable starter rope,

remove the spark plug lead to prevent the engine from

starting accidentally. Ground the lead to prevent sparks

that could cause fires. Make sure the equipment is in

neutral.

Figure 5. Control Panel.

Choke Lever

Choke On

Choke Off

 

Содержание Command 6 HP

Страница 1: ...1 COMMAND 6 HP HORIZONTAL CRANKSHAFT OWNER S MANUAL...

Страница 2: ...severe burns Stop engine before filling fuel tank WARNING Explosive Fuel Gasoline is extremely flammable and its vapors can explode if ignited Store gasoline only in approved containers in well ventil...

Страница 3: ...ry when servicing batteries Before disconnecting the negative ground cable make sure all switches are OFF If ON a spark will occur at the ground cable terminal which could cause an explosion if hydrog...

Страница 4: ...amage A logo or symbol on oil containers identifies the API service class and SAE viscosity grade See Figure 3 3 U S Quart Capacity Fuel Tank Start Stop Switch Optional Oil SentryTM Light Fuel Shut Of...

Страница 5: ...it should be 90 octane minimum Unleaded gasoline is recommended as it leaves less combustion chamber deposits Leaded gasoline may be used in areas where unleaded is not available and exhaust emission...

Страница 6: ...o not use gasoline left over from summer Figure 6 Location of Choke Lever Starting 1 Open fuel shut off valve 2 For a Cold Engine Place the throttle control midway between the slow and fast positions...

Страница 7: ...ngine to run at idle for 30 60 seconds 3 Move the throttle control to the stop position Or if equipped with optional start stop switch move the switch into the stop position 4 Close fuel shut off valv...

Страница 8: ...be overemphasized Check oil BEFORE EACH USE as follows 1 Make sure the engine is stopped level and is cool so the oil has had time to drain into the sump 2 To keep dirt debris etc out of the engine cl...

Страница 9: ...leaner cover retaining knob and remove the cover 2 Remove the precleaner from the paper element 3 Wash the precleaner in warm water with detergent Rinse the precleaner thoroughly until all traces of d...

Страница 10: ...e the element Handle new elements carefully do not use if the sealing surfaces are bent or damaged 5 When servicing the air cleaner check the air cleaner base Make sure it is secured and not bent or d...

Страница 11: ...the plug to keep dirt and debris out of the engine 2 Remove the plug and check its condition Replace the plug if worn or reuse is questionable NOTE Do not clean the spark plug in a machine using abras...

Страница 12: ...armed up This engine is equipped with a fixed main jet carburetor See Figure 11 Figure 11 Fixed Main Jet Carburetor The carburetor is designed to deliver the correct fuel to air mixture to the engine...

Страница 13: ...tions and add the correct amount for the capacity of the fuel system Fill the fuel tank with clean fresh gasoline Run the engine for 2 3 minutes to get stabilized fuel into the carburetor To empty the...

Страница 14: ...except catalytic mufflers which are warranted for two 2 years This warranty does not apply to defects caused by casualty or unreasonable use including faulty repairs by others and failure to provide r...

Страница 15: ...c For warranty repairs the engine must be presented to a Kohler Co service center as soon as a problem exists Call 1 800 544 2444 or access our website at www kohlerengines com for the names of the ne...

Страница 16: ...ny add on or modified part or malfunction of authorized parts due to the use of add on or modified parts MAINTENANCE AND REPAIR REQUIREMENTS The owner is responsible for the proper use and maintenance...

Отзывы: