background image

8

21

Check glass is vertical. If not

remove screws, re-drill and

re-fit as required.

Re-fit rubber strip over

screws

Drill 

4

 x 3mm holes

through jamb into wall

channel

STEP

10

STEP

11

Fit 

4 x 

   

  screws

B

Ensure glass panel is vertical

STEP

9

Slacken screws ‘A’. Push the glass panel into

the wall jamb. The glass should be 2mm lower

than the top of the wall jamb. Tighten screws ‘A’

when the glass is in the correct position

STEP

13

B

OPERATION

Warm Up Function (Optional)

1.

   Press the 

Warm Up

 push-button.

2.

   The unit delays turning on to allow you to get out 

 

of the shower.

3.

   The 

Warm Up

 push-button flashes for a number of 

 

seconds until water comes out of the handset at the desired temperature.

4.

   When the water is at the desired temperature the unit turns off waiting for you to shower.

To Operate the Shower

1.

   Press the 

Low, Medium or High

 flow push-button.

2.

   Water will come out of the handset at the desired temperature.

3. 

  To alter the showering temperature, turn the temperature control knob. Whilst the showering temperature

 

stabilises, the selected flow push-button will flash.

4. 

 Press the 

Off 

push-button at the end of your shower.

Caution!

Anyone who may have difficulty understanding or operating the controls of any shower should be attended 

whilst showering. Particular consideration should be given to:

 • 

the 

young

 

• the elderly

 • 

the 

infirm

 • 

the 

disabled

 

• anyone who suffers from a medical condition that can result in temporary incapacity (e.g. epilepsy or    

 

  blackouts).

 

• anyone inexperienced in the correct operation of the controls.

Low, Medium or High Flow Button 

- Buttons glow 

BLUE

 when pressed

Temperature

Control Knob

Warm Up/Off Button 

glows 

BLUE

when powered

CFI230G

CFI230G

Carefully remove the Water Delivery System

from the Water Delivery Wall Jamb.

A

STEP

12

Содержание CFI230G

Страница 1: ...ra Magna Shower System 646 Fitting Instructions 1 2 3 4 1 2 3 4 Slide Rail Fixed Head Kohler Daryl Limited Alfred Road Wallasey Wirral CH44 7HY England Tel 44 0 151 606 5000 Fax 44 0 151 638 0303 www...

Страница 2: ...olumn box The Shower Enclosure is subject to the Daryl Showering Lifetime Guarantee and for the Shower System the Mira Showers 5 year guarantee applies Please refer to the Guarantee Registration Docum...

Страница 3: ...r Daryl Glass Treatment and Daryl Glass Protector Available in one care kit the Treatment and Protector are used on new or existing shower installations where Protector has not already been applied an...

Страница 4: ...ith a pH value of 4 to 8 applied with a soft cloth Under no circumstances should scourers or powerful detegents be used as these can damage the metallic surface of the frame and also tarnish the glass...

Страница 5: ...ctrical supply isolated or fuse blown Digital Mixer Valve breakdown Spray plate assembly blocked Hose blocked or twisted A small amount of water may be retained in the shower fitting after the shower...

Страница 6: ...of the glass panel fits into slot A on the tray The wall channel end sits on the flat section of the tray B A B Handset Adjustment To adjust the height of the handset press the release button A and sl...

Страница 7: ...tart Soothe and Massage and an Eco setting To adjust the spray setting turn the spray plate as follows 1 Start Water flows from the outer set of holes To select the Start setting turn the spray plate...

Страница 8: ...r To Operate the Shower 1 Press the Low Medium or High flow push button 2 Water will come out of the handset at the desired temperature 3 To alter the showering temperature turn the temperature contro...

Страница 9: ...STEP 17 Take care not to damage pipe and cable protruding from wall The lock mode may be activated when the unit is OFF in which case the unit cannot be switched ON unless the mode is cancelled as ab...

Страница 10: ...d momentarily hold the Warm Up and High keys at the same time Release the push button and reselect within 2 seconds The two keys will flash twice and beep three times to confirm the selection is succe...

Страница 11: ...EP 22 Note The lintel is supplied as a RH unit For LH versions loosen the panel clamps and turn them through 180o Ensure glass panels are parallel to each other Loosely fit the parking block into the...

Страница 12: ...screw B on each panel clamp until it grips the glass IMPORTANT DO NOT OVER TIGHTEN Fit caps to lintel C A B Remove the lintel from glass and remove the parking block 1 Match parking block to mark on...

Страница 13: ...he Suppression Ferrite close to the Water Delivery connector Note The Suppression Ferrite is packed with the Digital Mixer Fit the fixed roller to the tray on the same side as lintel wall fixing Note...

Страница 14: ...ller and plastic glass guide Caution Whilst supporting the weight of the door slide the bottom roller into the bottom track Caution 14 CFI230G 15 CFI230G STEP 32 STEP 33 STEP 31 STEP 35 STEP 37 STEP 3...

Отзывы: