Carefully 

measure and mark pattern

 on wall 

board surface as shown in 

figure 11

This pattern applies to:

NOTE: 

Measurements from edges, top and 

base. All dimensions below are in millimeters.

• Flat shower walls

 

• Flat bath walls

 

• The flat sections of

moulded walls

DURACRYL WALL INSTALLATION CONT...

30

50

30

250

300

80

Adhesive 

Pa

tter

n

Pattern on wall board

Adhesive 

Pa

tter

n

Pattern on rear of wall liner

Pattern on wall board

Pattern on rear of wall liner

W

all Liner position already marked

Tray recess

Tray recess

CORNER

CORNER

Fig.11: Adhesive pattern for Flat Walls 

MARKING ADHESIVE PATTERN

For moulded shower walls, the pattern must be marked on both wall board 

and

 rear of Duracryl liner. 

Refer to 

gures below for both patterns: • Corner Contour & Corner Contour PLUS Wall - 

• Side Recessed Wall - 

At this stage it is essential that the back side of the Duracryl wall and the surface of the wall board 
are wiped clean with a damp cloth. This will ensure that all dust is removed from both surfaces and 
provide a clean surface for the adhesive. Allow both surfaces to dry before adhesive application.

Fig.12: Adhesive pattern for Corner

Contour and Corner Contour PLUS Walls

30

50

30

410

450

80

Adhesive 

Pa

tter

n

wallboard

recess

wallboard

recess

Packing Blocks

*Leave top block intact

to support the shelves.

*Carefully cut the lower

block to fit around nog.

W

all Liner position already marked

CORNER

CORNER

Fig.13: Adhesive pattern for
Side Recessed Walls

Mark the pattern but do not
apply adhesive at this stage.

When applying adhesive
it is vital to leave gaps in the
bead to allow solvent curing.

!

IMPORTANT

figure 12

figure 13

Adhesive 

Pa

tter

n

30

30

80~100

Pattern on wall board

Adhesive

Pattern

W

all Liner position already marked

Tray recess

CORNER

DURACRYL WALL

Содержание BATH WALL

Страница 1: ...t technology to innovative design it s all to make your showering experience the very best it can be INSTALLATION INSTRUCTIONS Flat Shower Wall Corner Contour PLUS Flat Bath Walls 1123738 F January 2020 Note Bath and bath screen not included Side Recessed Shower Wall Corner Contour PLUS Shower Walls DURACRYL WALL CORNER CONTOUR PLUS CORNER CONTOUR FLAT WALL SIDE RECESSED WALL BATH WALL ...

Страница 2: ...corner Side Recessed Walls there should be no interference within 400mm of the corner on the side that the moulded shelving egresses into the framing cavity Instructions drawings and diagrams contained in this manual present information available at the time of printing Although every attempt has been made to keep them up to date Kohler Company reserves the right to implement product changes witho...

Страница 3: ...ve sealant pack 3 sided wall liner for metallic black framed showers Adhesive sealant pack 3 sided wall liner for white framed showers The recommended adhesive and sealants are to adhere the acrylic liner to the wallboard to seal the acrylic liner to the shower tray or bath Sika Shower Bond Sika Sikasil NG White Usage 3 cartridges for 2 sided wall liners 4 cartridges for 3 sided wall liners These ...

Страница 4: ...50 739 864 984 964 1000 X 1000 X 1000 884 864 900 X 900 X 900 900 X 750 X 900 885 747 D 2 0 C 2 0 B 2 0 A 2 0 A B WALL BOARD 984 984 1000 X 1000 884 884 900 X 900 900 X 750 734 884 884 1184 1200 X 900 Fig 2 Corner 2 sided Wall Fig 1 Alcove 3 sided Wall Double studs for shower wall retainers Double studs for shower wall retainers Double studs Note Dimensions are to the finished surface of wallboard...

Страница 5: ...vity space and ensure there is no interference or obstructions eg plumbing electrical wires insulation 2 Construct timber framing as shown in When paired with an Englefield Quick Fit Low Profile shower tray 60 70mm sill height the Side Recessed Shower Wall Liner is designed to be compatible with standard 90mm deep framing with vertical studs at 400mm or 600mm centres and horizontal nogs at 800mm a...

Страница 6: ... debris can get into the waste hole For bath tubs use a drop cloth For shower trays select appropriate size then cut base protector from back of shower tray carton Place it in shower tray as per figure 6 Mark and drill holes required for outlet fittings as per figure 7 NOTE Follow the drilling and cutting instructions from page 3 Position wall in place Check fit to ensure wall fits squarely into corn...

Страница 7: ...our PLUS Wall Side Recessed Wall At this stage it is essential that the back side of the Duracryl wall and the surface of the wall board are wiped clean with a damp cloth This will ensure that all dust is removed from both surfaces and provide a clean surface for the adhesive Allow both surfaces to dry before adhesive application Fig 12 Adhesive pattern for Corner Contour and Corner Contour PLUS W...

Страница 8: ...shown on previous page 50 mm m m 0 1 SILICONE ADHESIVE 5 mm ADHESIVE BEAD APPLYING THE ADHESIVE Fig 14 Cutting cartridges Apply sealant to shower tray or bath first as shown in below Apply a bead of sealant for 50 mm from both front corners at base of upstand as shown Apply a second full length bead at top of upstand Fig 15 Apply beading to upstand Page 8 figure 14 figure 15 figures 12 13 Ensure th...

Страница 9: ... soft clean cloth to press firmly and remove any rippling along glue lines Check and re press if necessary For corner mouldings re install the shelves while the adhesive is setting Allow the adhesive to cure before installing the shower or bath and or using the enclosure CLEANING INSTRUCTIONS Use non abrasive soap and warm water Avoid harsh chemicals and disinfectants abrasive cleaners solvent base...

Отзывы: