The following list contains abbreviations that may appear in this publication.

A, amp

ampere

ABDC

after bottom dead center

AC

alternating current

A/D

analog to digital

ADC

analog to digital converter

adj.

adjust, adjustment

ADV

advertising dimensional
drawing

AHWT

anticipatory high water
temperature

AISI

American Iron and Steel
Institute

ALOP

anticipatory low oil pressure

alt.

alternator

Al

aluminum

ANSI

American National Standards
Institute
(formerly American Standards
Association, ASA)

AO

anticipatory only

API

American Petroleum Institute

approx.

approximate, approximately

AR

as required, as requested

AS

as supplied, as stated, as
suggested

ASE

American Society of Engineers

ASME

American Society of
Mechanical Engineers

assy.

assembly

ASTM

American Society for Testing
Materials

ATDC

after top dead center

ATS

automatic transfer switch

auto.

automatic

aux.

auxiliary

A/V

audiovisual

avg.

average

AVR

automatic voltage regulator

AWG

American Wire Gauge

AWM

appliance wiring material

bat.

battery

BBDC

before bottom dead center

BC

battery charger, battery
charging

BCA

battery charging alternator

BCI

Battery Council International

BDC

before dead center

BHP

brake horsepower

blk.

black (paint color), block
(engine)

blk. htr.

block heater

BMEP

brake mean effective pressure

bps

bits per second

br.

brass

BTDC

before top dead center

Btu

British thermal unit

Btu/min.

British thermal units per minute

C

Celsius, centigrade

cal.

calorie

CARB

California Air Resources Board

CB

circuit breaker

cc

cubic centimeter

CCA

cold cranking amps

ccw.

counterclockwise

CEC

Canadian Electrical Code

cfh

cubic feet per hour

cfm

cubic feet per minute

CG

center of gravity

CID

cubic inch displacement

CL

centerline

cm

centimeter

CMOS

complementary metal oxide
substrate (semiconductor)

cogen.

cogeneration

Com

communications (port)

conn.

connection

cont.

continued

CPVC

chlorinated polyvinyl chloride

crit.

critical

CRT

cathode ray tube

CSA

Canadian Standards
Association

CT

current transformer

Cu

copper

cu. in.

cubic inch

cw.

clockwise

CWC

city water-cooled

cyl.

cylinder

D/A

digital to analog

DAC

digital to analog converter

dB

decibel

dBA

decibel (A weighted)

DC

direct current

DCR

direct current resistance

deg.,

°

degree

dept.

department

dia.

diameter

DI/EO

dual inlet/end outlet

DIN

Deutsches Institut fur Normung
e. V.
(also Deutsche Industrie
Normenausschuss)

DIP

dual inline package

DPDT

double-pole, double-throw

DPST

double-pole, single-throw

DS

disconnect switch

DVR

digital voltage regulator

E, emer.

emergency (power source)

EDI

electronic data interchange

EFR

emergency frequency relay

e.g.

for example (

exempli gratia)

EG

electronic governor

EGSA

Electrical Generating Systems
Association

EIA

Electronic Industries
Association

EI/EO

end inlet/end outlet

EMI

electromagnetic interference

emiss.

emission

eng.

engine

EPA

Environmental Protection
Agency

EPS

emergency power system

ER

emergency relay

ES

engineering special,
engineered special

ESD

electrostatic discharge

est.

estimated

E-Stop

emergency stop

etc.

et cetera (and so forth)

exh.

exhaust

ext.

external

F

Fahrenheit, female

fglass.

fiberglass

FHM

flat head machine (screw)

fl. oz.

fluid ounce

flex.

flexible

freq.

frequency

FS

full scale

ft.

foot, feet

ft. lbs.

foot pounds (torque)

ft./min.

feet per minute

g

gram

ga.

gauge (meters, wire size)

gal.

gallon

gen.

generator

genset

generator set

GFI

ground fault interrupter

GND,

ground

gov.

governor

gph

gallons per hour

gpm

gallons per minute

gr.

grade, gross

GRD

equipment ground

gr. wt.

gross weight

H x W x D height by width by depth
HC

hex cap

HCHT

high cylinder head temperature

HD

heavy duty

HET

high exhaust temperature

hex

hexagon

Hg

mercury (element)

HH

hex head

HHC

hex head cap

HP

horsepower

hr.

hour

HS

heat shrink

hsg.

housing

HVAC

heating, ventilation, and air
conditioning

HWT

high water temperature

Hz

hertz (cycles per second)

IC

integrated circuit

ID

inside diameter, identification

IEC

International Electrotechnical
Commission

IEEE

Institute of Electrical and
Electronics Engineers

IMS

improved motor starting

in.

inch

in. H

2

O

inches of water

in. Hg

inches of mercury

in. lbs.

inch pounds

Inc.

incorporated

ind.

industrial

int.

internal

int./ext.

internal/external

I/O

input/output

IP

iron pipe

ISO

International Organization for
Standardization

J

joule

JIS

Japanese Industry Standard

k

kilo (1000)

K

kelvin

kA

kiloampere

KB

kilobyte (2

10

bytes)

Содержание 7ER

Страница 1: ...Commercial Mobile Generator Sets Model 7ER TP 6034 10 02a Installation...

Страница 2: ......

Страница 3: ...nce Requirements 8 4 3 Exhaust Piping If Used 8 Section 5 Fuel System 9 5 1 Fuel Tank 9 5 2 Fuel Lines 10 5 3 Fuel Pump Lift and Fuel Consumption 10 5 4 Fuel Filters or Strainers 10 Section 6 Electric...

Страница 4: ...TP 6034 10 02 Table of Contents Notes...

Страница 5: ...reconnecting the battery Follow these precautions to prevent the starting of the generator set by the remote start stop switch Battery Sulfuric acid in batteries Can cause severe injury or death Wear...

Страница 6: ...xide is an odorless colorless tasteless nonirritating gas that can cause death if inhaled for even a short time Avoid breathingexhaustfumeswhenworking on or near the generator set Never operate the ge...

Страница 7: ...se severe injury or death Operate the generator set only when all guards and electrical enclosures are in place Moving rotor WARNING Hazardous voltage Backfeed to the utility system can cause severe i...

Страница 8: ...t system can ignite adjacent combustible materials Do not locate electrical wiring fuel lines or combustible materials above the exhaust muffler Exercise caution when parking your vehicle to prevent t...

Страница 9: ...itute with inferior grade hardware Screws and nuts are available in different hardness ratings To indicate hardness American Standard hardware uses a series of markings and metric hardware uses a nume...

Страница 10: ...VI Safety Precautions and Instructions TP 6034 10 02 Notes...

Страница 11: ...following and state and local requirements The installer is responsible for improper installations resulting in penalties from noncompliance with CARB or EPA emission standards 1 2 Generator Set Spec...

Страница 12: ...2 Introduction TP 6034 10 02 Notes...

Страница 13: ...em components See the current generator set specification sheet or Section 7 of this manual for generator set dimensions and weights For angular operating limits consult the operation manual 2 3 Vehic...

Страница 14: ...ADV 6450 E Figure 2 1 Extended Shaft Dimensions Figure 2 2 shows a Kohler mobile generator set mounted to a hydraulic pump The generator set equipped with the extended shaft option can power external...

Страница 15: ...e intake restriction The engine generator performance will be adversely affected if these guidelines are neglected Follow these guidelines to optimize generator set performance Model Normal Intake Res...

Страница 16: ...6 Cooling System TP 6034 10 02 Notes...

Страница 17: ...e seek fresh air immediately and remain active Do not sit lie down or fall asleep Alert others to the possibility of carbon monoxide poisoning Seek medical attention if the condition of affected perso...

Страница 18: ...cent combustible materials 4 3 Exhaust Piping If Used Route the exhaust piping to maintain minimum clearances and to minimize exhaust piping bends Use a tail pipe as short as possible with as few bend...

Страница 19: ...atch fuel when draining thefuel system Wipe up spilled fuel after draining the system 5 1 Fuel Tank Fuel system design Design the generator set gasoline fuel system to operate independently of the veh...

Страница 20: ...1 4 in ID Flexible hose sections If a metal fuel line draws fuel from the fuel tank install a flexible hose section to connect the metal line to the fuel pump The flexible section allows generator set...

Страница 21: ...exhaust system and drippage of fuel oil or grease Allow at least a 51 mm 2 in clearance between the electrical wiring and hot exhaust parts Do not locate the wiring directly below or near the fuel sys...

Страница 22: ...otect the AC load circuit of the generator set against overloading or short circuiting with a circuit breaker s Note For standby service connect output of the generator to a suitably rated transfer sw...

Страница 23: ...in the STOP position 2 Disconnect the power to the battery charger if equipped 3 Remove the battery cables negative lead first Reconnect the negative lead last when reconnecting the battery Follow th...

Страница 24: ...s for the following three reconnection systems using circuit breakers Two pole circuit breaker with a single voltage system example 120 volt 3 wire Attach stator leads marked 2 and 4 to the side of th...

Страница 25: ...ate battery the battery can be installed closer to the generator set and the cable length can be minimized to eliminate voltage drop See Figure 6 2 for the minimum cold cranking amps CCA battery recom...

Страница 26: ...ure gauge if equipped D Water temperature gauge if equipped D Battery voltage D Hourmeter D Start Stop switch including run light Available panels D Start Stop switch with hourmeter D Start Stop switc...

Страница 27: ...Installation Drawing 17 TP 6034 10 02 Section 7 Installation Drawing ADV 6450 E Figure 7 1 Dimension Drawing...

Страница 28: ...TP 6034 10 02 18 Installation Drawing Notes...

Страница 29: ...o not connect the load side terminals of the circuit breaker See Figure 8 1 If the installation requires a 100 120 volt 2 wire system use a single pole circuit breaker See Figure 8 2 When connecting s...

Страница 30: ...tator Leads L0 GRD L2 L1 L0 Neutral Line Side Factory Two Pole Circuit Breaker Ground Load Side 100 120 200 240 Volt 3 Wire 60 Hz 50 Hz L0 L1 100 120 Volt 100 120 Volt L0 L2 100 120 Volt 100 120 Volt...

Страница 31: ...regulator Voltage regulator adjustments are possible without removing the voltage regulator The voltage regulator adjustment procedure applies to the PowerBoost IIIE Figure 8 5 voltage regulator Note...

Страница 32: ...an electrical outlet 4 Start the generator set 5 Rotate the voltage adjustment pot clockwise to increase the voltage counterclockwise to decrease the voltage to the desired output voltage 6 Rotate the...

Страница 33: ...age of each generator set operated lamp Note that not all of the lights or lamps are on the generator set AC circuit some are DC powered by a 12 volt battery Ensure that the calculated total wattage i...

Страница 34: ...oled cyl cylinder D A digital to analog DAC digital to analog converter dB decibel dBA decibel A weighted DC direct current DCR direct current resistance deg degree dept department dia diameter DI EO...

Страница 35: ...al OS oversize overspeed OSHA Occupational Safety and Health Administration OV overvoltage oz ounce p pp page pages PC personal computer PCB printed circuit board pF picofarad PF power factor ph phase...

Страница 36: ......

Страница 37: ......

Страница 38: ......

Страница 39: ......

Страница 40: ...Kohler Wisconsin 53044 Phone 920 565 3381 Fax 920 459 1646 For the nearest sales service outlet in the US and Canada phone 1 800 544 2444 KohlerPowerSystems com Kohler Power Systems Asia Pacific Head...

Отзывы: