1. Install AC power unit (sticke
r on the back) dry, and avoid
showering, soaking from water. Customer prepare wire
tube and wire according to requirement. Wire tube
should be put into the wall. Suggested wire: AC connection
wire should with insulated protecting layer or sleeve and
the section should be bigger than 0.5mm . The section of
DC connection wire should be
bigger than 0.3mm . The
connection pattern must according to illustrations above.
2. After wire layout finished, check and repair if needed.
Then connect AC connector of AC/DC transformer to
electrical source from the control box, and DC connector of
AC/DC transformer to faucet. Turn on AC electrical power,
Faucet will commence auto-sense mode which will take
30s.
The faucet will
not
work this period
.
直流连接线采用导体标称截面积
mm
的电线。
请严格按照上图进行连接。
0.3
1.
电源盒
(
背面有不干胶
)
应安装在干燥,不会被水
淋湿、浸泡的位置。根据需要客户自备穿线管及
连接线。穿线管安装在墙内。建议交流电源线采用
带绝缘和护套层的电线,导体标称截面积
0.5mm
;
2.
排线完毕后,应检查并确保所有排、接线无误,
2
2
2
2
再分别连接电源盒
AC
接线端与排线管内交流接线
端,以及电源盒
DC
接线端(黑橙线接头)与龙头
的电源线接插件(从阀盒内引出的电线),最后
打开
AC
电源,龙头进入
30
秒自动调距阶段,此过
程龙头不会出水。
1364728-T01-A