TROUBLE SHOOTING
Symptoms
Probable Causes
Corrective Action
No battery or wrongly connected
No power supply or wrong connection
Object in sensing range
Dirt on the sensing window
The connector does not connect well
Check the batteries
Check the power supply and the conncetion
Remove the object
Clean the sensing window
Check the connector
No water flow
(Indicator not flashing)
The indicator flashes 1
times every second and
the water doesn't flow out.
Batteries are out of power
Just power cut
DC or AC connector of AC/DC transformer
may not connect well
Replace batteries
Check the power supply
Reconnect the connector
Just finishing installation
The connector assemblies are closed
Aerator is blocked
The filter is blocked
Wait for 30s
Open the connector assemblies
Clean the aerator
Clean filter
No water flow while
the indicator flashes
The connector assemblies are not open
completely
The filter is blocked
Aerator is dirty
The supply water pressure is lower
Turn counterclockwise the adjustment bolts on
connector assemblies with the hex wrench
Clean filter
Clean the aerator
Check the water supply system
Low water flow while the
indicator does not flash
Keep water out within 1 minute
while indicator does not flash
Object in sensing range
Remove object
The indicator flashes every
3 seconds and the water
flow out.
Batteries are out of power
Replace batteries
The indicator flashes 3
times every second and
the water doesn’t flow out.
Batteries are out of power
Replace batteries
Please contact with distributor or Kohler China Investment Co., Ltd., if the trouble remains after above-mentioned actions are taken.
Please do not disassembly the other parts of the faucet freely except installing and replacing batteries.
Some trouble symptoms can be identified by the indicator's flashing.
(
Refer to "Note of the Indicator Flashing"
)