COMPLETE THE INSTALLATION 

□  Turn on the water supply to the valve.
□  Check all connections for leaks and make any adjustments as needed.
□  Press the icon on the interface. The interface screen will be lit and the shower should be turned on.

NOTE:

 For more information about using the user interface and its menus, refer to the user interface.

□  Check for leaks and make any adjustments as needed.
□  Verify that the water flow is sufficient for your showering needs. Remove the regulator in the outlet of the 

valve if needed.

NOTE

: The maximum water temperature to the outlets is limited to 120°F (49°C). The valve will automatically 

shut down if the temperature exceeds 120°F (49°C).

INSTALLATION CHECKOUT

NOTES:

 Do not plug in the power cord until all interface cables are connected. 

NOTES:

 Make drip loops in all cables and cords.

□  Route the interface cable(s) in the wall from the valve location to the interface installation locations.
□  If not already installed, install the interface(s) at this time according to the instructions packed with

the product.
□  Connect the interface cable(s) to the valve.
□  Verify there is power to the electrical outlet.
□  Plug the power cord into the outlet.

OPERATION INSTRUCTIONS

How to Operate the Interface

Showerhead Symbol 

- (Top Button) 

Turn showerhead On/Off.

Handshower Symbol

 - (Bottom Button)

Turn handshower On/Off.

NOTES: Showerhead and handshower can be used at 

the same time.

Rotary movement selects showering temperature. The 

larger the number which the temperature setting mark 

is aligned, the higher the temperature. “C” is for full 

cold water, “H” is for pre-set Max temperature.

NOTE: 

The factory default maximum temperature is 

set to 45°C. And the default maximum time of water 

outflow is 30 minutes

it will be turned off automatically 

after 30 minutes.
When you turn on the product and water begins to 

flow, the temperature indicator light will begin to flash 

to show the product is warming up. Once the prese

-

lected outlet temperature has been reached, the 

indicator light will stop flashing.
Press the buttons on the handshower to change the

water flow.

Remote Control

Turn the shower On/Off.

Through the remote control, showerhead and 

handshower will be turned off at the same time. 

But only showerhead will be turned on by default.

Remote Control

Showerhead 

Symbol
Handshower

Symbol

Temperature Indicator

Temperature 

Setting Mark

SETTINGS

When the shower is in the off 

position, hold down the showerhead 

button for 10 seconds

the lights will 

pulse slow to indicate setting mode.

 

Adjust temperature indicator according 

to the table below to set desired 

maximum temperature. The scale on 

the indicator which the temperature 

setting mark is aligned represents the 

selected maximum temperature.

Caution!

 Make sure that the maximum 

outlet temperature is suitable and safe 

for all users.

Temp Indicator Position

Temp (°C)

C

Exit No Change

1 - 3

41

4 - 6

45

7 - 9

48

H

Exit No Change

Press the showerhead button to 

set the maximum temperature. 

The temperature indicator light will 

flash three times to confirm the 

setting has been completed.

Temperature Indicator

Temperature Setting Mark

CARE AND MAINTENANCE

Clean the Inlet Screen

Disconnect the power and turn off the water supply.
Unthread the plastic nuts from the hot and cold inlets.
Remove the copper tubes. The O-ring and screen may be 

attached to the end of the tube.
If the screen remains in the check valve, use a small 

flat-blade screwdriver to gently pull the check valve from the 

valve inlets.
Remove the screens from the copper tubes or check valves.
Clean the screens to remove any dirt or debris. Rinse or 

replace the check valves and screens. Reassemble the inlet 

connections.

Clean the Handshower 

Any debris or mineral build-up may cause distorted flow 

stream or reduce the flow rate. To remove the debris or 

mineral build-up, run water through the handshower, firmly 

press or rub your finger back and forth across the rubber 

nozzles.
Remove and clean the screen washer.

Uninstall the Button of the Interface

Insert one end of a hex wrench into the hole on the 

backplate to remove the button, replace it if needed during 

maintenance

Screen

Nut

Copper Tube

Check Valve

Seal

O-Ring

Hex Wrench

Hole

   

                                                                          

1354659-2A-C

                      

                                                                                                                              

9

   

  

   

                                                                          

1354659-2A-C

                    

                                                                                                                                

8

   

  

Содержание 22327T-7

Страница 1: ...lve components Doing so will damage valve components 7 Do not use oil based non setting compounds such as plumbers putty on the threaded connections 8 Observe all plumbing electrical and building code...

Страница 2: ...rewdrivers Pipe Wrench Hacksaw or Tube Cutter Wood Saw Hammer Sealant Tape level Adjustable Wrench Drill 21 33 205 99 259 340 25 29 30 9 19 38 6 48 64 41 Dual Shower UI Remote Control 35 25 3 25 3 30...

Страница 3: ...tional Extension Line 5 metres Interface Exension Lead Remote Control Exension Lead Dual Shower UI Remote Control Outlet 1 For Showerhead Outlet 2 For Handshower 22327T 7 Dual Shower Set DTV MODE SERV...

Страница 4: ...Shower UI and Remote Control installation locations Install the Valve NOTES The Digital Mixer Valve may be installed in a loft space or in a convenient space provided enough room for maintenance Fail...

Страница 5: ...use Recommended Action Troubleshooting Table cont 11 No Lights on interface A Not connected to valve B No power to valve C Faulty user interface A Check connections connect if needed B Check power sup...

Страница 6: ...tion B Contact your Kohler Co Authorized Service Representative 5 Continuous flow A System will not switch off B Flow rate exceeds 10 gpm 45 5 L min from one outlet A Turn off the water and power supp...

Страница 7: ...valve may contain hot water Be careful when draining any residual water NOTES Turn off the power and water supply to the valve before performing any maintenance to the valve It is recommended that an...

Страница 8: ...lashing Press the buttons on the handshower to change the water flow Remote Control Turn the shower On Off Through the remote control showerhead and handshower will be turned off at the same time But...

Отзывы: