background image

INSTALLATION

Preparation

NOTES: Make sure both hot and cold supply pipes 

are flushed thoroughly prior to connection to the 

Digital Mixer Valve. 
If possible, install electrical outlet before installing the 

valve. Please turn off the electrical and water supplies 

before installation. Always keep the valve and outlet 

dry. Allow for enough slack in the cables for drip 

loops.
Remote Control can be installed outside showering 

enclosure, while the Dual Shower Interface is inside 

the showering enclosure. Determine all required 

components along with their installation locations 

before beginning installation. NOTES: The valve can 

not be connected to two interfaces at the same time.
When routing pipes, keep in mind each valve outlet 

must correspond to the appropriate showering compo-

nent for the preprogrammed or custom showering 

experiences to function properly. Please prepare 

cable tubes before routing cables as the dimension. 
NOTES: The showerhead fill supply line must be 

routed from outlet 1, and the handshower is from 

outlet 2. Port A is for the dongle(not provided, 23777T) 

connection, port B is for joining cable.

Installation Steps

□  Mark the fixing holes in required positions,drill three 

holes on mounting surface according to the rough-in 

dimensions and diameter of the anchors(2).

□  Press anchors into the holes, install and secure 

Digital Mixer Valve in position with fixing screws(1). 

NOTES: Install the offset foot(3) if needed.

□  Install nut A, the ring and nut B onto inlet/outlet. 

Hand-tighten nut A and nut B. Hold nut A with a 

wrench, meanwhile tighten nut B with another wrench. 

NOTES: The connector kit must be pushed into the 

end towards valve direction

tighten it firmly.

□  Connect hot and cold water supply pipes to Digital 

Mixer Valve.

□  Route pipes from valve outlet to the installation 

locations of showerhead and wall-mount connection. 

□  Route cables from valve to the Dual Shower UI and 

Remote Control installation locations.

Install the Valve

NOTES

The Digital Mixer Valve may be installed in a 

loft space or in a convenient space provided enough 

room for maintenance. Failure to do so may result in 

an inability to carry out any maintenance.

Installation Direction of the Valve

Do not mount the valve with the inlets located at the  

top. 

Do not 

mount the valve with the inlets or cable  

sockets pointing up.Vertical and horizontal mounting  

options are shown as the figure.

Vertical

Horizontal

Drip Loop

Drip Loop

Cable 1m 

Electrical Outlet

Remote Control

Dual Shower

UI

Outlet1

(Showerhead)

Inlet(Cold)

Outlet 2

(Handshower)

Inlet(Hot)

Cable 10m 

Adaptor

Cable 10m 

Nut B

Nut A

Ring

1

2

3

Electrical Outlet

Inlet(Cold)

Inlet(Hot)

Outlet1

(Showerhead)

Outlet 2

(Handshower)

Connector Kit

Statistics of Contents of Toxic or Hazardous Substances or Elements

Connection Assy

Interface Assy

×

×

×

×

Faucet Assy

Part name

Toxic or Hazardous Substance or Elements

Lead

(

Pb

)

Mercury

(

Hg

)

Cadmium

(

Cd

)

Hexavalent

Chromium

Cr

(

VI

)

Polybrominated

biphenyls

PBB

Polybrominated

Diphenyl Ethers 

PBDE

○:

Indicates that the substance in the material composition is below the high limits of the current requirements in 

GB/T 26572.

×:

Indicates that at least one of the homogeneous substance in the material composition is above the high limits 

of the current requirements in GB/T 26572.

Note: the information provided is based on the supplier data and Kohler inspection results. The product is 

designed not to hurt the environment. Under current technology, all hazardous materials have been used in the 

smallest amounts possible. Kohler will strive to reduce the use of these hazardous materials used in this product.

The product “service life for environment protection” is 10 years;   Kohler Company will specify product 

service life based on product characteristics.  The product “service life for environment protection” is only 

effective when the product is used as described in the product specification. 

Valve

Cable Tube

Min R40

Min Ø25

Port A

Port B

Joining Cable

   

                                                                          

1354659-2A-C

                    

                                                                                                                              1

3

   

  

   

                                                                          

1354659-2A-C

                    

                                                                                                                              

  4

   

  

Содержание 22327T-7

Страница 1: ...lve components Doing so will damage valve components 7 Do not use oil based non setting compounds such as plumbers putty on the threaded connections 8 Observe all plumbing electrical and building code...

Страница 2: ...rewdrivers Pipe Wrench Hacksaw or Tube Cutter Wood Saw Hammer Sealant Tape level Adjustable Wrench Drill 21 33 205 99 259 340 25 29 30 9 19 38 6 48 64 41 Dual Shower UI Remote Control 35 25 3 25 3 30...

Страница 3: ...tional Extension Line 5 metres Interface Exension Lead Remote Control Exension Lead Dual Shower UI Remote Control Outlet 1 For Showerhead Outlet 2 For Handshower 22327T 7 Dual Shower Set DTV MODE SERV...

Страница 4: ...Shower UI and Remote Control installation locations Install the Valve NOTES The Digital Mixer Valve may be installed in a loft space or in a convenient space provided enough room for maintenance Fail...

Страница 5: ...use Recommended Action Troubleshooting Table cont 11 No Lights on interface A Not connected to valve B No power to valve C Faulty user interface A Check connections connect if needed B Check power sup...

Страница 6: ...tion B Contact your Kohler Co Authorized Service Representative 5 Continuous flow A System will not switch off B Flow rate exceeds 10 gpm 45 5 L min from one outlet A Turn off the water and power supp...

Страница 7: ...valve may contain hot water Be careful when draining any residual water NOTES Turn off the power and water supply to the valve before performing any maintenance to the valve It is recommended that an...

Страница 8: ...lashing Press the buttons on the handshower to change the water flow Remote Control Turn the shower On Off Through the remote control showerhead and handshower will be turned off at the same time But...

Отзывы: