4. Connect the Wires
Apply grease (provided) to the sensor socket located on the
circuit board inside the cover. This will provide additional
corrosion protection.
Connect the handle switch and sensor wires from the faucet to
the circuit board.
Connect the power cord to the circuit board.
Connect the solenoid wire to the circuit board.
Plug the power cord into an unswitched 120 VAC outlet. The
power LED on the circuit board will illuminate.
Test activation of the sensor. Refer to the
″
Faucet Operation
″
section.
Handle Switch
Solenoid
Power Cord
Sensor
Solenoid
Power
LED
Cover
Apply grease.
1276182-2-C
8