3. Make the Electrical Connections – USA
WARNING: Risk of electric shock.
Make sure the power has been disconnected before performing
the following procedures.
WARNING: Risk of electric shock.
Connect the blower motor to a properly grounded,
grounding-type receptacle protected by a Ground-Fault Circuit-Interrupter (GFCI) or Residual
Current Device (RCD). Do not remove the grounding pin from the plug. Do not use a grounding
adapter.
NOTICE:
The blower motor is equipped with a cord and plug. A qualified electrician must install a GFCI-
or RCD-protected, 120 V, 15 A, grounded outlet for the blower. No other load should be on this circuit.
Install an electrical outlet behind the bath, at least 1-1/2
″
(38 mm) above the subfloor, and within
reach of the 24
″
(610 mm) power cord.
Plug the blower into this outlet.
Install a GFCI-protected
120 V, 15 A grounded outlet.
Bond in accordance
with applicable codes.
Air Intake
24" (610 mm) Max. Distance
Between Blower and Outlet
Kohler Co.
7
1198326-2-A