(0.1 bar). Double checkvalves fitted in the inlet supply to the appliance cause a 

pressure build up, which affect the maximum static inlet pressure for the appliance 

and must not be fitted. For Fluid category 5 double checkvalves are not suitable.

9. 

The showerhead should be positioned so that it discharges down the centre line 

of the bath or across the opening of a shower cubicle.

10. 

Only use the inlet connections supplied with the product. 

DO NOT

 use any other 

type of fittings.

11. 

All pipework must be checked for leaks before the product installation is 

completed. The product should be pressurised and the inlet & outlet connections 

inspected.

12. DO NOT 

overtighten connections, screws or grubscrews as product damage 

may occur.

13. 

Upon completion of installation, or if the product is dismantled during installation 

or servicing, then the product must be inspected to ensure that there are no leaks.

14. 

Having completed the installation, make sure that the user is familiar with the 

operation of the product.

Zone of 

Backflow Risk

30 mm 

Minimum

Toilet or Bidet 

FC

5

Hand Basin 

FC3

Bath or Shower 

Tray FC3

Mixer 

Shower

25 mm 

Minimum

25 mm Minimum

8. 

The position of the shower and 

shower  fittings  must  provide  a 

minimum gap of 25 mm between 

the showerhead and the spill 

over level of any bath, shower 

tray or basin and a minimum 

gap of 30 mm between the 

showerhead and the spill over 

level of any toilet, bidet or other 

appliance with a Fluid Category 

5 backflow risk (see diagram).

Note!

 There will be occasions when 

the hose retaining ring will not provide 

a suitable solution for Fluid Category 

3 installations, in these instances an 

outlet double checkvalve must be 

fitted, this will increase the required 

supply pressure typically by 10kPa 

Содержание 1190330-NA

Страница 1: ...TOMER AND MUST BE RETAINED WITH THE PRODUCT FOR MAINTENANCE AND OPERATIONAL PURPOSES Installation and User Guide Built In Shower Valve MODEL NUMBERS Important Please quote the above model number s whe...

Страница 2: ...res and Flow Rates 6 Dimensions 7 Installation 8 Suitable Plumbing Systems 8 General 8 Reversing the Outlet Position 10 Installation Procedure 11 Operation 15 Commissioning 16 Maximum Temperature Sett...

Страница 3: ...ith these instructions and must be conducted by designated qualified and competent personnel 4 Pass on this guide in the event of change of ownership of the installation site 5 Follow all warnings cau...

Страница 4: ...ppliance to thaw and check for leaks before using 17 Insulate any pipework that could be exposed to freezing conditions 18 The water supplies to this product must be isolated if the product is not to...

Страница 5: ...5 1095640 W2 B PACK CONTENTS Or q 1 x Mixer Valve Single Sequential Temperature Only q 1 x Building in Shroud q 1 x Adapter Pack q 3 x Screws q 3 x Wall Plugs...

Страница 6: ...mperatures Optimum performance is obtained when temperature differentials of 20 C or more exist between blend and either supply Blend control accuracy will begin to diminish at temperature differentia...

Страница 7: ...7 1095640 W2 B DIMENSIONS All dimensions are nominal and in mm 140 16 77 140 53 Single Sequential Temperature Only 16 77 53...

Страница 8: ...se instructions and must be conducted by designated qualified and competent personnel The installation must comply with the Water Supply Regulations 1999 Water Fittings or any particular regulations a...

Страница 9: ...on or if the product is dismantled during installation or servicing then the product must be inspected to ensure that there are no leaks 14 Having completed the installation make sure that the user is...

Страница 10: ...d 2 Remove the outlet blanking plug using a 12 mm hexagonal wrench 3 Screw the outlet adapter complete with O seal into the bottom hole previously blanked and tighten 4 Screw the outlet blanking plug...

Страница 11: ...e side of the mixer This is to prevent the flexible hose from obstructing the shower controls 2 Remove the shroud screw retain for later use and remove the mixer from the building in shroud 3 Determin...

Страница 12: ...ting e g timber noggin to the front of the wall before tiling 7 Make sure that the mixer is level central in the hole and square to the finished wall surface or the control components will not fit cor...

Страница 13: ...nstallations alternative fixings may be required not supplied to fix the mixer to the rear face of the wall cavity or to a timber noggin 11 Make sure that the olives are fitted connect the hot and col...

Страница 14: ...nly The Temperature Adapter must be fitted before the trim kit 19 1 Fit the Spline Adapter to the cartridge 19 2 Fit the retaining screw into the centre of the spline adapter Tighten the screw 19 3 Fi...

Страница 15: ...Turning the control knob anti clockwise will increase the flow and temperature from off through cold to the preset maximum Temperature Only Turning the control knob anti clockwise will increase the t...

Страница 16: ...Adapter until the grubscrew can be seen in the cutout then unscrew the grubscrew approx 2 turns 3 2 Remove the temperature adapter and the adapter ring 3 3 Unscrew and remove the Hub Retaining Screw...

Страница 17: ...17 1095640 W2 B Hub Retaining Screw Temperature Adapter Single Sequential Temperature Only Cartridge Drive Adapter Maximum Temperature Setting Cartridge Adapter Ring Adapter Cutout Grubscrew...

Страница 18: ...tory a Check strainers and inlet outlet fittings for flow restriction b Make sure that the minimum flow rate is sufficient for the supply conditions c Make sure that the dynamic inlet pressures are no...

Страница 19: ...icant types may cause rapid deterioration of seals Cleaning The chrome plated parts should be cleaned using a mild washing up detergent or soap solution rinsed and then wiped dry with a soft cloth War...

Страница 20: ...ing of residual water 4 Continue to unscrew and remove the non return valve assembly Caution Some residual water may be released 5 The non return valve assembly and or strainer screens can be cleaned...

Страница 21: ...pplied 1595 070 Component Pack identified A 1624 102 Screw Pack identified B 1624 109 Seal Pack identified C 408 71 Flat Faced Insert 1624 113 Outlet Adaptor 1624 114 Blanking Plug 1624 110 Filter Non...

Страница 22: ...22 1095640 W2 B NOTES...

Страница 23: ...23 1095640 W2 B NOTES...

Страница 24: ...esolve any material defects by providing replacement parts modules or complete product as we deem appropriate To be free of charge work must be undertaken by Kohler approved personnel To ensure that a...

Отзывы: