background image

1112263-9-A

©2009 Kohler Co.

Dome

Screw

Mounting Nut

Valve Spline

Handle

Plug Button

O-Ring

Washer

Bonnet

Valve

Limit Stop

Faucet 
Body

Seal

Check Valve 
with O-ring

Spacer

Seal

Plug 
Button

Screw

Screw

Handle

Bonnet

Handle

Bonnet

Handle

Bonnet

Handle

Bonnet

Plug 
Button

O-Ring

Screw

Plug Button

Setscrew

Setscrew

SERVICE KIT INSTRUCTIONS

1108711

SPACER ASSEMBLY KIT

†

Place the new seal into the faucet body.

†

Insert the O-ring end of the new check valve into the new spacer.

†

Properly seat the new spacer on the seal in the faucet body.

†

Securely wrench tighten the mounting nut to the faucet body.

†

Press the limit stop on the valve spline, then position the limit stop at the mark on the valve.

†

Securely hand tighten the bonnet.

†

Reinstall the handle.

†

Turn on the water supply. Check for leaks and proper operation.

Install

†

Turn off the water supply. Lift the handle to relieve the water pressure.

†

Identify your handle type in the illustration, then disassemble the faucet according to the illustration.

†

Turn the bonnet counterclockwise to remove it from the faucet body.

†

Mark the limit stop on the valve to ensure correct realignment.

†

Slide the limit stop off of the valve spline.

†

Turn the mounting nut counterclockwise to remove it from the faucet body.

†

Extract and discard the vacuum breaker (not shown), check valve with O-ring, and seal from the
faucet body.

Remove