The other firebox fixing method is as follows :-
In installations where the cable method is not suitable (e.g. loose masonary in rear
of fire opening) the firebox can be secured to the fire surround using four screws
and wall plugs provided. Below (fig.12) is a diagram to indicate the hole centre
positions available on the firebox to facilitate the screw fixing to the fireplace /
surround.
Fig. 12
2.3
GAS TIGHTNESS AND INLET PRESSURE
a)
Remove the pressure test point screw from the inlet elbow and fit a
manometer.
b)
Turn on the main gas supply and carry out a gas tightness test.
c)
Depress the control knob and turn anti-clockwise to the position marked
pilot. Hold in the control knob for a few seconds to purge the pipe work
then press the igniter button. The burner should light, continue to hold
the control knob for a few seconds then turn to the full-on position.
d)
Check that the gas pressure is
20.0 mbar (+/- 1.0 mbar) 8.0 in w.g.(+/-
0.4 in w.g.)
e)
Turn off the fire, remove the manometer and refit the pressure test point
screw. Check the pressure test point screw for gas tightness with the
appliance turned on using a suitable leak detection fluid or detector.
17
260mm
37mm
532mm
425mm
Firebox
Mounting
Flange
Содержание KRDPB0RN