Order Codes
●
Mounting
bracket
PSU-BR
●
Parts for panel
mount
PM100
●
Front protection
cover
KB100
●
Mini clamp wire mount
plug
PSU-M
●
Communication cable (1)
●
Sensor controller
●
USB-RS485 converter
●
Termination resistance connector
Cable length
005RL : 50 mm [1.969 in.]
1RL : 1000 mm [39 in.]
3RL : 3000 mm [118 in.]
1RLN : 1000 mm [39 in.] one end has no connector (loose wires)
Cable included
Blank : USB (mini-B)
⇔
USB (A), male
N : Cable not included
IBFL-K-TR
Cable included
(USB cable)
50 mm [1.969 in.]
Loose
wires
-1RL
-3RL
-1RLN
-005RL
Cable(*2)
Blank: None
3L: 3000 mm [118 in.] power supply, switch cable (for no MSU communications)
5L: 5000 mm [197 in.] power supply, switch cable (for no MSU communications)
3LD: 3000 mm [118 in.] power supply, switch, communication cable (for MSU-232)
5LD: 5000 mm [197 in.] power supply, switch, communication cable (for MSU-232)
3LE: 3000 mm [118 in.] power supply, switch cable (for MSU-485) (*3)
5LE: 5000 mm [197 in.] power supply, switch cable (for MSU-485) (*3)
Front protection cover (*1)
Blank: None
C: With protective
front cover
Mounting parts
Blank: None
B: With mounting bracket
P: With panel mount parts
Output method
Blank: NPN output type
PNP: PNP output type (*5)
Communication specifications
Blank: No communication
232: RS232C communication
485: RS485 communication (*4)
●
Pressure sensor head
Piping options
Blank: None
UR4:
φ
4 reducer
UR6:
φ
6 reducer
M5: M5 inline
Cable orientation
L: Vertical out
S: Horizontal out
Pressure range
EA : -101.3 to 0 kPa [-29.9 to 0 inHg]
ER : -100 to 220 kPa [-29.5 to 65.0 inHg]
EM : -100 to 1000 kPa [-29.5 to 295 inHg]
MSU - PH -
-
-
●
Power supply/switching/communication cable
MSU - K -
IBFL - K -
IBM2A - H1 -
*1) Protective front cover -C can be selected only if panel mount parts -P are
selected.
*2) 3L and 5L can be selected only if no communication is selected
3LD and 5LD can be selected only if -232 is selected
3LE and 5LE can be selected only if -485 is selected
*3) Communication cables are sold separately. Purchase by selecting
IBFL-K-
□
separately.
*4) When using RS485 communications, be sure to connect a termination
resistance connector.
*5) Only NPN type is UL compliant.
*When using RS485 communications, be sure to connect a termination resistance connector.
Cable type
3L: 3000 mm [118 in.] power supply, switch cable (for no MSU communications)
5L: 5000 mm [197 in.] power supply, switch cable (for no MSU communications)
3LD: 3000 mm [118 in.] power supply, switch, communication cable (for MSU-232)
5LD: 5000 mm [197 in.] power supply, switch, communication cable (for MSU-232)
3LE: 3000 mm [118 in.] power supply, switch cable (for MSU-485)
5LE: 5000 mm [197 in.] power supply, switch cable (for MSU-485)
3HE: 3000 mm [118 in.] sensor head extension cable
5HE: 5000 mm [197 in.] sensor head extension cable
MSU - - - - -