811

Specifications

Item

Measurement flow rate range

Response

Output signal

Operating temperature range

Storage temperature range

Operating and storage humidity range

Operating pressure range

Proof pressure

Output voltage accuracy

Repeatability

Pressure characteristics

Temperature characteristics

Power supply voltage

Allowable voltage fluctuation range

Output stabilization time

Consumption current

Dielectric strength

Insulation resistance

Connection method

Material

Mounting direction

Mounting conditions

Straight piping length

Vibration resistance

Mass

Electrical connection 
(special connectors) 

FS-R05

Air/nitrogen. However, the detection media cannot contain chlorine, sulfur, acid, or other corrosive substances. Gas must also be dry.

Gas must be clean gas devoid of dust and mist (oil mist).

500

〜+

500 m

R

/min [

30.5

30.5 in.

3

/min.]

Converted volume flow rate at 20°C [68°F], 1 atm [14.7 psi.]

5 ms or less (95% response to stepped changes in flow rate)

DC1

5V (nonlinear characteristics), Allowable load resistance 10 k

Ω

or more

0

50°C [32

122°F] (for both ambient temperature and measured media temperature)

10

60°C [14

140°F] 

10

80%RH (no condensation)

100

〜+

200 kPa [

14.5

29.0 psi.] (Pressure characteristic warranty range is 

70

〜+

200 kPa [

10.2

29.0 psi.])

300 kPa [43.5 psi.]

±

5%FS MAX.

0.0

R

/min [0.000 ft.

3

/min.]: 3.00

±

0.20V

0.1

R

/min [0.004 ft.

3

/min.]: 3.77

±

0.20V

0.3

R

/min [0.011 ft.

3

/min.]: 4.53

±

0.20V

0.5

R

/min [0.018 ft.

3

/min.]: 5.00

±

0.20V

±

2%FS MAX.

Assuming the same temperature and pressure conditions at time of measurement

±

0.01%FS/kPa

In 

70

〜+

200 kPa [

10.2

29.0 psi.] pressure range

0.0

R

/min [0.000 ft.

3

/min.]: 

±

0.1%FS/°C

0.3

R

/min [0.011 ft.

3

/min.]: 

±

0.15%FS/°C

DC24V (supplied from sensor controller)

In the DC21.6

26.4V range, 

±

2%FS or less in relation to output value at DC24V

Note 2

Time required to come within 

±

5%FS of final attained voltage (flow rate): Instantaneous

Time required to come within 

±

1%FS of final attained voltage (flow rate): Within 10 sec.

12 mA MAX.

Between all external connector terminals and body: AC500V for 1 min., or AC600V for 1 sec.

Between all external connector terminals and body: 50 M

Ω

(at DC500V megger)

M5 female thread (brass insertion), tightening torque at 2.5 N·m [1.84 ft·lbf] or less

Gas contact part: PPS plastic (flow path body), ceramic (substrate), brass (connections)

Cover part: PC plastic (polycarbonate)

Any direction except where cover part faces downward

When using the mounting holes on this device, use M3 screws and a tightening torque of 0.6 N·m [5.3in·lbf] or less. 

In addition, install a filter upstream from the device that is capable of collecting dust and mist particles of 10

μ

m or larger.

Unnecessary either upstream or downstream from the device

10

55 Hz, total amplitude 1.5 mm [0.059 in.], XYZ directions each two hours

9 g [0.32 oz.]

Cable with dedicated connector

Flow rate sensor heads side: SM03B-SRSS-G-TB made by JST Mfg. Co., Ltd.

Mating side: SHR-03V-S-B (housing), SSH-003GA-P0.2 (contact) made by JST Mfg Co., Ltd.

FS-10

0

〜+

10

R

/min [0

0.35 ft.

3

/min.]

±

5%FS MAX.

0.0

R

/min [0.000 ft.

3

/min.]: 1.00

±

0.20V

3.0

R

/min [0.106 ft.

3

/min.]: 3.89

±

0.15V

5.0

R

/min [0.177 ft.

3

/min.]: 4.46

±

0.15V

10.0

R

/min [0.353 ft.

3

/min.]: 5.00

±

0.20V

±

6%FS MAX.

±

0.01%FS/kPa (0

〜+

200 kPa [0

29.0 psi.])

±

0.03%FS/kPa (

70

0 kPa [

10.2

0 psi.])

0.0

R

/min [0.000 ft.

3

/min.]: 

±

0.1%FS/°C

5.0

R

/min [0.177 ft.

3

/min.]: 

±

0.2%FS/°C

Model

Flow rate sensor heads

Notes: 1. The %FS in the table assumes full-scale output voltage of 4V (1

5V).

2. Near the upper limit of the measurement flow rate range, output fluctuation after flow rate stabilization can be generated up to a maximum of  

±

1%FS

(amount of drift 500 seconds after flow rate stabilization).

FS-R3

3

〜+

3

R

/min [

0.11

0.11 ft.

3

/min.]

±

5%FS MAX.

0.0

R

/min [0.000 ft.

3

/min.]: 3.00

±

0.15V

0.5

R

/min [0.018 ft.

3

/min.]: 3.88

±

0.15V

1.5

R

/min [0.053 ft.

3

/min.]: 4.49

±

0.15V

3.0

R

/min [0.106 ft.

3

/min.]: 5.00

±

0.20V

±

3.5%FS MAX.

±

0.01%FS/kPa

0.0

R

/min [0.000 ft.

3

/min.]: 

±

0.1%FS/°C

1.5

R

/min [0.053 ft.

3

/min.]: 

±

0.15%FS/°C

Gases targeted for 
measurement

Standard flow rate 
characteristics

Содержание Flow FSU

Страница 1: ...um valve ON Workpiece lifted by vacuum Vacuum break L R min L2 L1 ΔL Reference flow rate capture ON t Switch output Hysteresis Discharge to atmospheric pressure Vacuum valve ON Workpiece lifted by vacuum Vacuum break L R min L1 L2 ON t Switch output Hysteresis Hysteresis Discharge to atmospheric pressure Vacuum valve ON Workpiece lifted by vacuum Vacuum break Window comparator mode 2 When L1 has b...

Страница 2: ... and controller Attempting to connect the sensor head with the power on could cause erratic operation in the controller due to surge voltage etc DANGER While the product is in operation do not attempt to adjust the attached mechanisms connecting and disconnecting the wiring connector or attach or position the sensor head etc Abnormal operations could result in injury General precautions 1 If power...

Страница 3: ... be careful to avoid applying excessive force on the lead wires 4 3 2 1 1ch PSUW FS 2ch 3ch 4ch The connector for 4 sensor head Connector for power supply switch and communication cable Power supply switch and communication cable Sensor head Lock lever Lock lever Cover Sensor head side connector Attaching and removing of the sensor head and the power supply switch and communication cable Attaching...

Страница 4: ...g preparation Connect the connectors to the sensor heads See p 801 for the connection procedure for the sensor head connectors Connect the sensor heads one to four pcs and the power supply switch and communication cable to the controller See p 801 for attaching and removing of the sensor head and the power supply switch and communication cable Setting procedure Window comparator mode 1 CO1 Window ...

Страница 5: ...m hold Flow rate display deleted Output mode check Sensor head type check ON ΔL OFF point check Reference flow rate ΔL OFF point check Switch output condition display Version display Reference flow rate capture method using general purpose I O input 24V SW PIN 1 0 5V or less 10 ms or longer Captured at startup 1 2 3 4 PIN SW PIN 1 1 2 3 4 PIN 1 c h 4 c h Flow rate sensor head Multi channel flow ra...

Страница 6: ...rocedure to switch off the flow rate display Flow rate display switch off Procedure 1 2 3 4 5 Device operation 7 seg display Remark 7 seg LED off 7 seg LED re lighted Use the following procedure to switch the flow rate display to autoscan mode Since autoscan mode is combined with the key lock function no key operation other than cancellation of autoscan can be performed Note Autoscan mode is cance...

Страница 7: ...and bottom hold cannot be implemented at the same time Peak hold and bottom hold Procedure 1 2 3 4 5 6 7 Peak hold 7 seg display Remark Hold start Hold cancel Bottom hold 7 seg display Error Display Error display n is the targeted channel n is the targeted channel Error cancel In the case of a wire break shut off the power and replace the sensor head Correct the error and then press the mode key f...

Страница 8: ...eresis width setting for Channel 4 HYS1 1 1 1CH 2 2CH 3 3CH 4 4CH Always input 1 Signal name DC24V 0V OUT1 OUT2 OUT3 OUT4 0V RXD TXD RTS CTS Controller side Personal computer side D sub 25 pin configuration Pin No 1 2 3 4 5 6 7 8 9 10 11 Signal name D G TXD RXD RTS CTS DSR DCD DTR Pin No 7 2 3 4 5 6 8 20 Serial communication cable Power and switch output cable D sub 9 pin configuration Signal name...

Страница 9: ... Enabled for window comparator mode 4 only Function Sets switch output reversed not reversed Send example INV1 0c rl f Response example OK c rl f Response example NG c rl f 21 illegal type I N V 1 0 1 1CH 2 2CH 3 3CH 4 4CH 0 Not reversed 1 Reversed P1 1 1CH 2 2CH 3 3CH 4 4CH C Function Displays the L1 ΔL and L2 points for each channel Send example C1 c rl f Response example 1 00 c rl f L1 ΔL 0 50 ...

Страница 10: ...LED Send example DIS 1 c rl f Response example OK c rl f Response example NG c rl f 21 illegal type DIS 1 1 Not lighted 0 Lighted AS Function Sets ON OFF for autoscan function Send example AS 1 c rl f Response example OK c rl f Response example NG c rl f 21 illegal type AS 1 1 ON 0 OFF PHL Function Sets ON OFF for peak hold function Send example PHL 1 c rl f Response example OK c rl f Response exa...

Страница 11: ... Sensor Sensor Sensor Sensor Main circuit Main circuit Main circuit Main circuit Reference flow rate capture Reference flow rate capture Sensor head 3ch Sensor head 4ch Brown V Blue 0V Black analog voltage output Brown V Blue 0V Black analog voltage output Main circuit Multi channel flow rate sensor controller Power supply and switch output cable Brown SW4 Black 0V Yellow SW3 Green SW2 White Red V...

Страница 12: ...w comparator mode 3 Window comparator mode 4 Compatible with window comparator mode 4 only Variable Can be freely set at 2 digits or more 7 segment LED 3 digit display Red LED lights up when ON Flow rate display channel green LED lights up UP DOWN MODE Conforms with RS232C 10 50 C 14 122 F storage 20 80 C 4 176 F no condensation and freezing IEC61000 4 4 Power supply line 1KV level 2 Sensor input ...

Страница 13: ...o come within 1 FS of final attained voltage flow rate Within 10 sec 12 mA MAX Between all external connector terminals and body AC500V for 1 min or AC600V for 1 sec Between all external connector terminals and body 50 MΩ at DC500V megger M5 female thread brass insertion tightening torque at 2 5 N m 1 84 ft lbf or less Gas contact part PPS plastic flow path body ceramic substrate brass connections...

Страница 14: ... Flow rate sensor head PM100 KB100 Mini clamp wire mount plug PSU M Power supply switch and communication cable Sensor head connecting cable Flow rate sensor head FS PSUK PSUW Communication cable Blank No communication cableNote 1 D With communication functionNote 2 Cable length 3L 3000 mm 118 in 5L 5000 mm 197 in Cable length 3L 3000 mm 118 in 5L 5000 mm 197 in Power supply switch and communicati...

Страница 15: ... clamp wire mounting socket PSUK Dimensions mm in Model PSUK 3L PSUK 5L L 3000 118 5000 197 7 8 0 307 30 1 181 5 0 197 2 65 0 1043 2 M2 6 0 45 Depth 6 0 236 27 6 1 087 32 1 260 5 3 0 209 40 1 575 40 1 575 4 digit LED flow rate indicator Mode button LED red A S OUT SW OUT ch 1 2 3 4 FSU LED green DOWN button UP button 4 switch output indicators 4 autoscan channel indicators Mounting thread The conn...

Страница 16: ...al communication cable Note 3 leads 7 0 276 PSUW 2 φ4 5 0 177 9 0 354 11 0 433 4 5 0 177 16 0 630 11 0 433 2 φ2 9 0 114 9 6 0 378 7 0 276 24 0 945 7 0 276 30 1 181 4 0 157 38 1 496 12 6 0 496 1 6 0 063 PSU BR Model PSUW 3L PSUW 5L L 3000 118 5000 197 Note Only PSUW D is available Hex socket head screw M2 6 0 45 length 5 0 197 2 screws provided MULTI CHANNEL FLOW RATE SENSOR CONTROLLERS Notes 1 The...

Страница 17: ...for vacuum breaking flow Flow rate sensor head Vacuum Valve Unit with flow rate sensor CRCB 0064W V P R V Vacuum port R Exhaust port P Pressure port Adjusting needle for vacuum breaking flow Flow rate sensor head Micro ejector with flow rate sensor CRCB 0065W Note For detailed specification and dimension consult us ...

Отзывы: