GS1-50
●
The set pressure and operating pressure are indicated
on the same pressure gauge. Panel mounting offers
convenient centralized control and management built into
the control panel.
●
An indicator is standard equipment, to check the switch
operation state. Wiring connection methods offered
include a standard grommet (lead wire) type, and a DIN
connector type as an option.
Symbol
Specifications
Dimensions
(mm)
Order Codes
Voltage
AL
For AC100V, AC200V
DL
For DC24V
Wiring
Blank
Lead wire
T
With DIN connector
GS1-50
–
–
–
Pressure gauge with built-in switch
(outer diameter 50mm)
GS1-50
●
With DIN connector
Remark: A model with built-in contact protection circuit
(external surge absorption element) is available.
For details, consult us.
φ45
φ18
1.5
M5×0.8
R1/4
(6)
(49.5)
52.5
35
14
φ5
52.5
40
52.5
40
MPa
-
+
0.1
0.2
0.3
0.4
0.5 0.6
0.7
0.8
1
29.6
(2.4
)
φ14.8
(4.6)
14.8
(7.6)
(25)
(32.5)
7.5
13
M12×1.25
0.9
0
MPa
-
+
0.1
0.2
0.3
0.4
0.5 0.6
0.7
0.8
1
0.9
0
Indicator
2-M4
×
0.7, Depth: 7
Thread for panel mounting
Pressure regulation screw
Outer diameter of
pressure gauge
Appro
x.
500
(Width across flats)
(Width across flats)
Non-ion specification
Blank
Standard specification
NCU
Non-ion specification
Item
Model
GS1-50
Air
0.83 [120]
5
〜
60 [41
〜
140]
0
〜
1.0 [0
〜
145]
F.S.
±
3
%
0.1
〜
0.83 [14
〜
120]
±
0.05 [
±
7]
±
0.05 [7] (5
〜
45°C [41
〜
113°F])
0.07 [10] max.
Micro switch
a
contact (NO)
Lead wire length : About 500mm [19.7in.]
Note 2
DIN connector
Standard equipment: LED for DC, neon lamp for AC
9.8 [1]
Any
0.17 [6.0] (0.19 [6.7] with DIN connector)
Aluminum die-casting
SPCC
Brass
Brass
Media
Maximum operating pressure
MPa [psi.]
Operating temperature range (atmosphere and media)
°C [°F]
Pressure indicator range MPa [psi.]
Indicator accuracy
Pressure adjusting range MPa [psi.]
Regulating pressure indication error
Notes 1 and 3
MPa [psi.]
Repeatability
Note 3
MPa [psi.]
Hysteresis
MPa [psi.]
Contact type
Wiring
Standard
Option
Indicator
Shock resistance
m/s
2
[G]
Mounting direction
Materials
Body
Flats of nipple section
Bourdon tube
Pressure
gauge
specifications
Switch
specifications
Notes: 1. Shows when the pressure is rising.
2. Made to order is available at
-1L
: 1000,
-2L
: 2000,
-3L
: 3000mm.
3. Regulating pressure indicator errors and repeatability errors could be accumulated.
(Maximum
±
0.1MPa [
±
14.5psi.]). Be aware of this during use.
Operating Current Range
0.01
〜
0.5
0.01
〜
0.3
0.01
〜
0.2
Non-inductive load
Operating current range
Rated voltage
DC30V
AC125V
AC250V
Inductive load
Continuous
0.05
〜
0.1
0.5 MAX.
0.01
〜
0.1
0.5 MAX.
0.01
〜
0.05
0.2 MAX.
Inrush
A
PRESSURE GAUGES WITH
BUILT-IN SWITCH
Mass
kg [oz.]
Case