5
6
Specifications
Model
Item
DTY-ELG41-
□
Input voltage
V
DC24±5%
Current consumption
mA
100 or less
Output voltage
kV
Approx. 2.5 (high frequency type)
Display
Power/discharge
Power ON: Indicator LED (green) flashing
Discharge: Indicator LED (green) ON
Alarm
Alarm indicator LED (red) ON
Lighting LED
White LED
Lighting LED switch
Normally OFF/Normally ON/Lever sync
Outer dimensions
mm [in.]
For gun shape: 177.3(L)×32(W)×127.9(H) [6.980(L)×1.260(W)×5.035(H)]
For straight shape: 222.2(L)×32(W)×50(H) [8.748(L)×1.260(W)×1.969(H)]
(not including protrusions)
Mass
g [oz]
DTY-ELG41: 185 [6.53]
DTY-ELG41-PAU: 235 [8.29]
(without cables)
Ion balance
*1
V
±15
Pulse frequency
*2
Hz
5 to 15
Ozone generation amount
*3
ppm
0.04 or less
Medium
*4
Air (clean air, water vapor and oil removed)
Operating air pressure range MPa [psi]
DTY-ELG41: 0.05 to 0.6 [7 to 87]
DTY-ELG41-PAU: 0.2 to 0.6 [29 to 87]
Operating Environment
Indoors: 0 to 40°C [0 to 104°F]/65% or less (non-condensation)
Material
Body: PBT, Nozzle: PPS
Accessories
AC Adapter, Instruction Manual
*1: Distance 100mm [3.937 in.] from nozzle port, pressure 0.4MPa [58 psi], standard nozzle
2: Depending on the piping conditions and the nozzle used, the frequency/flow characteristics may differ.
3: Distance 200mm [7.874 in.] from nozzle port, pressure 0.2MPa [29 psi]
4: Be sure to supply air when using.
Remark 1: Ion balance is measured according to our measurement conditions.
2: Do not use other nozzles other than the dedicated one. Do not alter the nozzle. Doing so could cause the product to fail, stop working, and break.
3: The tube must be
φ
6 in diameter and be 3m [9.840 ft] or less in length. Otherwise, the electrostatic charge removal performance/pulse blow
operation could be affected.
Do not replace the fitting.
Order codes
●
Main unit
DTY-ELG41-
□
Cable length: 2000mm [78.740 in.]
Blank
: No pulse blow unit
PAU
: Pulse blow unit built in
AC adapter (accessory)
Rating
Input : AC100 to 240V
50/60Hz 0.3A
Output : DC24V 0.5A
Cable length: 1200mm [47.244 in.]
NOTE
-PAU cannot perform contin-
uous blow. To use continuous
blow, select "Blank".
DTY-ZEM-G31
●
Options (sold separately)
Replacement discharge
needle
(unit: 5 per set)
AC
adapter
(1200mm [47.244 in.])
Replacement nozzle
DTY-Z
□
-G31
Replacement of discharge needle
When replacing the discharging needle, use the dedicated tool
DTRY-ELB21
in combination with a torque driver. The dedicated tool is designed not
to damage the discharge needle or the threaded part of the main body. Replacing with another tool may cause damage to the discharge needle and
main body, etc. The tightening torque during replacement must be 15 to 20N·cm [0.111 to 0.148 ft·lbf]. If the discharge needle is replaced without
using the dedicated tool and the discharge needle, main body, etc. are damaged, the warranty will not cover.
NOTE: When replacing the nozzle or take off the nozzle for the maintenance of the discharge needle, tighten the nozzle securely by hand without using a
tool. Tightening the nozzle with excess force could damage the threaded portion, etc.
DTY-ZPS-G31
N1
: Replacement nozzle
N2
: Extension nozzle
Extension cable
DTY-Z
□
-G31
CE3
: Extension cable 3m [9.840 ft]
CE5
: Extension cable 5m [16.400 ft]
Pulse blow unit
DTY-ZPA-G31
IN port
DTY-ZNP-G31
Special tool for replacing discharge needle
NOTE: Only bits are for sale.
DTRY-ELB21
6.35 [0.250]
9 [0.354]
22 [0.866]
φ
4.5 [0.177]
Shape of jig for replaceable bit
Label to apply to the pulse
blow frequency adjustment
trimmer section attached
* Label used to seal the trimmer section
when removing the pulse blow unit.
NOTE
The options are common to the
Static Electricity Removing Unit Ion-
izer-Air gun types DTY-ELG31 and
DTY-ELG41. For information about
DTY-ELG31, see "Catalog No.P407".
* Flex-resistant cable
Содержание DTY-ELG41