[Switch output response time setting]
5 ms Max
≒
20 ms
≒
100 ms
≒
1000 ms
[LCD display cycle setting]
250 ms
500
ms
1000
ms
[Backlight color setting]
Backlight OFF
When switch output OFF: Green When switch output ON: Red
When switch output OFF: Red
When switch output ON: Green
Always green
Always red
・
Linking to switch output links operation to which output channel 1.
Use this setting to set threshold values for each channel.
Change this setting in accordance with the cylinder model that the cylinder head will be set into.
Use this setting to configure backlight color settings.
This setting can be used to invert the switch output of each channel.
This setting can be used to change the display position of the sensor head LED indicator.
Input conditions
0<0FS<FS
0FS<FS<1000
The voltage differential between the 0FS position and FS position must be at least 1 V.
If these conditions are not met,
will appear on the display and the setting will be
disregarded.
Note 1: After changing this setting, you will need to perform initialization in order to return to the original setting.
2: After the scaling setting is changed, all of the threshold values become Upper Limit (L2) = FS Lower
Limit (L1) = 0FS. Configure the initialization value settings as required after changing this setting.
3: After the scaling setting is changed, the threshold value setting range is 0FS to FS.
With this setting, a location between two points is specified and scaling is performed.
Note 1: Input condition - Upper Limit (L2) > Lower Limit (L1) + 1
2: When the scaling setting is being used and the difference between its 0Fs and Fs values is 500 or greater,
use the following for the threshold value setting input condition: Upper Limit (L2) > Lower Limit (L1) + 10.
Threshold value setting (SET1)
Installed cylinder model setting (SET2)
Backlight display setting (SET7)
Switch output inversion setting (SET4)
LED display range setting (SET5)
Scaling setting (SET6)
Window comparator
Hysteresis
Upper limit (L2)
ON/OFF positions
ON position
Lower limit (L1)
ON/OFF positions
OFF position
Procedure Button operation Display after operation
Indicator
Backlight
Remarks
1
Green
Set the output range of each OUT.
2
(Initial default: 60) OUT flashing
Red
Set the upper limit value for indicator flashing.
3
Change the setting value as required.
4
(Initial default: 40)
Green
Set the lower limit value for indicator flashing.
5
Change the setting value as required.
6
(Initial default: 60) OUT flashing
Red
OUT2, OUT3: Repeat steps 2 through 5.
OUT4: Return to detection mode.
Procedure Button operation Display after operation
Remarks
1
Selects the model of the equipped cylinder.
2
3
(Initial default: 10)
4
Change the model number of the equipped cylinder.
5
After one second, returns to detection mode.
Procedure Button operation Display after operation
Remarks
1
2
Backlight setting
3
〜
4
After one second, returns to detection mode.
Use this setting to set the output mode for each channel.
Caution: Valid within the effective measuring range (operating range).
Output mode setting (SET3)
Procedure Button operation Display after operation
Remarks
1
Set the output range of each OUT.
2
Select the channel of each OUT.
3
〜
CH1: OUT1
CH2: OUT2
CH3: OUT3
CH4: OUT4
4
Select the output mode.
5
〜
: Output OFF
: Window comparator mode
: Hysteresis mode (Note)
6
*
Shows the channel number setting (1 second)
Shows the channel mode setting (1 second)
7
After one second, returns to detection mode.
Procedure Button operation Display after operation
Remarks
1
Set the contact type of each OUT.
2
Select the channel of each OUT.
3
〜
CH1: OUT1
CH2: OUT2
CH3: OUT3
CH4: OUT4
4
Select the contact type.
5
〜
: Non-inversion (A contact)
: Inversion (B contact)
6
*
Shows the channel number setting (1 second)
Shows the channel mode setting (1 second)
7
After one second, returns to detection mode.
Procedure Button operation Display after operation
Remarks
1
2
Set the display lower limit value.
3
(Initial default: 40)
4
Change the value as required.
5
Set the display upper limit value.
6
(Initial default: 60)
7
Change the value as required.
8
After one second, returns to detection mode.
Procedure Button operation Display after operation
Remarks
1
2
Move the cylinder to the lower limit value position.
3
(Initial default: 0)
Set the scaling lower limit value.
4
Change the value as required.
5
Move the cylinder to the upper limit value position.
6
(Initial default: 100) Set the scaling upper limit value.
7
Change the value as required.
8
After one second, returns to detection mode.
This setting can be used to return settings to their initial default values. It
also checks the display and output status at the same time.
This setting can be used to return settings to their initial default values.
Use this setting to configure the response time for switch output.
Use this setting to configure the display cycle of the LCD.
Caution: This operation will cause all switch outputs to momentarily change to ON.
Following this operation, all data will be initialized. If you need any current settings,
be sure to make a separate written copy of them before performing this operation.
Caution: Following this operation, all data will be initialized.
If you need any current settings, be sure to make a separate written copy of them
before performing this operation.
Initialization 2 (display, output check)
Initialization 1
Switch output response time setting (SET9)
LCD display cycle setting (SET8)
Error Indicators
Indicator
Meaning
Required action
The sensor head of the selected
channel is not connected or has
been disconnected.
In the case of disconnection, turn
off power and replace the sensor
head.
Invalid scaling setting.
Reconfigure the scaling setting
so it satisfies the required scaling
conditions.
Over voltage being applied to
sensor input.
After correcting for the source of
the problem, hold down the MODE
key for more than one second.
(n: applicable channel)
Over voltage being applied to
switch output.
Revision History
Ver. 2.0
P.2 Sensor head installation precautions added.
P.3 Corrected internal circuitry diagram.
P.5 Added models to installed cylinder model setting.
Use this setting to adjust the maximum output voltage of analog output.
Maximum output voltage of analog output adjustment (SETC)
Procedure Button operation Display after operation
Remarks
1
Adjust the maximum output voltage of analog output.
2
3
Shows voltage output from analog output.
4
Change value
Use a multimeter or other instrument to check
the analog output voltage as you adjust the
maximum output voltage.
5
After one second, returns to detection mode.
Procedure Button operation Display after operation
Remarks
1
Performs initialization. (Display check)
2
Press all three at the same time. Or, while
holding down
, press
and then
.
Procedure Button operation Display after operation
Remarks
1
Performs initialization.
2
Press all three at the same time. Or, while
holding down
, press
and then
.
Procedure Button operation Display after operation
Remarks
1
2
Output delay setting
3
〜
4
After one second, returns to detection mode.
Procedure Button operation Display after operation
Remarks
1
2
Sampling cycle setting
3
〜
4
After one second, returns to detection mode.
y
t
●
For other information, detailed specifications, and precautions, see the product catalog.
●
For inquiries about the product, contact your nearest Koganei sales office or the Overseas
Group noted below.
For information about other cylinders, contact Koganei.
Applicable cylinder Cylinder Bore SET2 number
NHC1D
All cylinders
10
NHL1D
All cylinders
10
NHB
□
PG(L)
All cylinders
10
NHB
□
P(A)
All cylinders
10
NHB
□
S
All cylinders
10
NHBDSL(G)
All cylinders
10
AFDPG
6, 18
15
8, 14
12
12
16
Applicable cylinder Cylinder bore SET2 number
MGA
All cylinders
20
TBDA
All cylinders
18
ARS
All cylinders
16
CDAS
SGDA
6
13
8
14
32
16
Other than above
15
MS
6, 10
18
16, 20
16