[Switch output response time setting]

    5 ms   Max
  

 20 ms

  

 100 ms

  

 1000 ms

[LCD display cycle setting]

 

250 ms

 500 

ms

 1000 

ms

[Backlight color setting]

 

Backlight OFF

 

When switch output OFF: Green  When switch output ON: Red

 

When switch output OFF: Red 

When switch output ON: Green

 

Always green

 

Always red

 Linking to switch output links operation to which output channel 1.

Use this setting to set threshold values for each channel.

Change this setting in accordance with the cylinder model that the cylinder head will be set into.

Use this setting to configure backlight color settings.

This setting can be used to invert the switch output of each channel.

This setting can be used to change the display position of the sensor head LED indicator. 

Input conditions

0<0FS<FS

0FS<FS<1000

The voltage differential between the 0FS position and FS position must be at least 1 V. 

If these conditions are not met, 

 will appear on the display and the setting will be 

disregarded. 

Note 1:  After changing this setting, you will need to perform initialization in order to return to the original setting.

2:  After the scaling setting is changed, all of the threshold values become Upper Limit (L2) = FS Lower 

Limit (L1) = 0FS. Configure the initialization value settings as required after changing this setting.

3:  After the scaling setting is changed, the threshold value setting range is 0FS to FS.

With this setting, a location between two points is specified and scaling is performed.

Note 1:  Input condition - Upper Limit (L2) > Lower Limit (L1) + 1

2:  When the scaling setting is being used and the difference between its 0Fs and Fs values is 500 or greater, 

use the following for the threshold value setting input condition: Upper Limit (L2) > Lower Limit (L1) + 10.

Threshold value setting (SET1)

Installed cylinder model setting (SET2)

Backlight display setting (SET7)

Switch output inversion setting (SET4)

LED display range setting (SET5)

Scaling setting (SET6)

Window comparator 

Hysteresis

Upper limit (L2)

ON/OFF positions

ON position

Lower limit (L1)

ON/OFF positions

OFF position

Procedure Button operation Display after operation

Indicator

Backlight

Remarks

1

Green

Set the output range of each OUT.

2

(Initial default: 60) OUT flashing

Red

Set the upper limit value for indicator flashing.

3

Change the setting value as required.

4

(Initial default: 40)

Green

Set the lower limit value for indicator flashing.

5

Change the setting value as required.

6

(Initial default: 60) OUT flashing

Red

OUT2, OUT3: Repeat steps 2 through 5. 

OUT4: Return to detection mode.

Procedure Button operation Display after operation

Remarks

1

Selects the model of the equipped cylinder.

2

3

(Initial default: 10)

4

Change the model number of the equipped cylinder. 

5

After one second, returns to detection mode.

Procedure Button operation Display after operation

Remarks

1

2

Backlight setting

3

 

 

4

After one second, returns to detection mode.

Use this setting to set the output mode for each channel.

Caution: Valid within the effective measuring range (operating range).

Output mode setting (SET3)

Procedure Button operation Display after operation

Remarks

1

Set the output range of each OUT.

2

Select the channel of each OUT.

3

 

 

CH1: OUT1

CH2: OUT2

CH3: OUT3

CH4: OUT4

4

Select the output mode.

5

 

 

: Output OFF

: Window comparator mode

: Hysteresis mode (Note)

6

 *

Shows the channel number setting (1 second)

Shows the channel mode setting (1 second)

7

 

After one second, returns to detection mode.

Procedure Button operation Display after operation

Remarks

1

Set the contact type of each OUT.

2

Select the channel of each OUT.

3

 

 

CH1: OUT1

CH2: OUT2

CH3: OUT3

CH4: OUT4

4

Select the contact type.

5

 

 

: Non-inversion (A contact)

: Inversion (B contact)

6

 *

Shows the channel number setting (1 second)

Shows the channel mode setting (1 second)

7

After one second, returns to detection mode.

Procedure Button operation Display after operation

Remarks

1

2

Set the display lower limit value.

3

(Initial default: 40)

4

Change the value as required.

5

Set the display upper limit value.

6

(Initial default: 60)

7

Change the value as required.

8

 

After one second, returns to detection mode.

Procedure Button operation Display after operation

Remarks

1

2

Move the cylinder to the lower limit value position.

3

(Initial default: 0)

Set the scaling lower limit value.

4

Change the value as required.

5

Move the cylinder to the upper limit value position.

6

(Initial default: 100) Set the scaling upper limit value.

7

Change the value as required.

8

After one second, returns to detection mode.

This setting can be used to return settings to their initial default values. It 
also checks the display and output status at the same time.

This setting can be used to return settings to their initial default values.

Use this setting to configure the response time for switch output.

Use this setting to configure the display cycle of the LCD.

Caution:  This operation will cause all switch outputs to momentarily change to ON.

Following this operation, all data will be initialized. If you need any current settings, 
be sure to make a separate written copy of them before performing this operation.

Caution:  Following this operation, all data will be initialized.

If you need any current settings, be sure to make a separate written copy of them 
before performing this operation.

Initialization 2 (display, output check)

Initialization 1

Switch output response time setting (SET9)

LCD display cycle setting (SET8)

Error Indicators

Indicator

Meaning

Required action

The sensor head of the selected 
channel is not connected or has 
been disconnected. 

In the case of disconnection, turn 
off power and replace the sensor 
head.

Invalid scaling setting.

Reconfigure the scaling setting 
so it satisfies the required scaling 
conditions.

Over voltage being applied to 
sensor input.

After correcting for the source of 
the problem, hold down the MODE 
key for more than one second.

 

 

(n: applicable channel)

Over voltage being applied to 
switch output.

Revision History

Ver. 2.0
P.2 Sensor head installation precautions added.
P.3 Corrected internal circuitry diagram.
P.5 Added models to installed cylinder model setting.

Use this setting to adjust the maximum output voltage of analog output.

Maximum output voltage of analog output adjustment (SETC)

Procedure Button operation Display after operation

Remarks

1

Adjust the maximum output voltage of analog output.

2

3

Shows voltage output from analog output.

4

Change value

Use a multimeter or other instrument to check 
the analog output voltage as you adjust the 
maximum output voltage.

5

After one second, returns to detection mode.

Procedure Button operation Display after operation

Remarks

1

Performs initialization. (Display check)

2

Press all three at the same time. Or, while 
holding down 

, press 

 and then 

Procedure Button operation Display after operation

Remarks

1

Performs initialization.

2

Press all three at the same time. Or, while 
holding down 

, press 

 and then 

Procedure Button operation Display after operation

Remarks

1

2

Output delay setting

3

 

 

 

4

After one second, returns to detection mode.

Procedure Button operation Display after operation

Remarks

1

2

Sampling cycle setting

3

 

 

4

After one second, returns to detection mode.

y

t

  For other information, detailed specifications, and precautions, see the product catalog.

  For inquiries about the product, contact your nearest Koganei sales office or the Overseas 

Group noted below. 

For information about other cylinders, contact Koganei. 

Applicable cylinder Cylinder Bore SET2 number

NHC1D

All cylinders

10

NHL1D

All cylinders

10

NHB

PG(L)

All cylinders

10

NHB

P(A)

All cylinders

10

NHB

S

All cylinders

10

NHBDSL(G)

All cylinders

10

AFDPG

 6, 18

15

8, 14

12

12

16

Applicable cylinder Cylinder bore SET2 number

MGA

All cylinders

20

TBDA

All cylinders

18

ARS

All cylinders

16

CDAS

SGDA

6

13

8

14

32

16

Other than above

15

MS

6, 10

18

16, 20

16