background image

A. LOCK/UNLOCK BUTTON: 

The pump has a 5-minute auto-lock, this light will turn on. To 

lock or unlock the pump, place a finger over the lock/unlock button for 3 seconds.

 

B. POWER-SAVING TIMER BUTTON: 

Designed to help avoid wasting power by setting the 

time and duration of the heating cycle for the spa. This way, you can enjoy your spa at the 

time you desire, without needing to leave the heater on at all times.

 

STEP 1

: Set the heating duration 

1.

 

Press the 

 button unit the 

 LED starts to flash. 

2.

 

Press the 

 or 

 button to adjust the heating duration (From 1-999 hours). 

3.

 

Press the 

 button again to confirm the heating duration. 

 

STEP 2

: Set the number of hours (from the current point) when the heater will activate 

1.

 

After setting the heating duration, the 

 LED starts to flash. 

2.

 

Press the 

 or 

 button to adjust the hours until time of activation (From 

0-999 hours). 

3.

 

Press 

 button again or simply touch nothing for 10 seconds to confirm the 

setting. The 0 LED will light steadily and the countdown to heater activation 

will begin. 

To modify the timer settings: Press the 

 button and use the 

 or 

 button to adjust. 

Cancel the setting: Press the 

 button for 2 seconds. 

 

 

POWER-SAVING TIMER LED: 

This flashing LED means you are setting the heating duration. The light will be on 

when the heating function starts to work. 
This flashing LED means you are setting the number of hours FROM NOW when 

the heater will activate. When the light is on, the Power-Saving Timer function is 

set.

 

NOTES: 

 

After setting, the screen flashes the current temperature and time alternately. 

 

Timer adjustment (amount of time with the heater ON) may be set from 1 to 999 

hours; Reservation time adjustment (the number of hours FROM NOW when the 

heater will begin to function) may be set from 0 to 999 hours. If the timer is set at 0 

hour, the heating system will activate immediately. 

 

The timer is one time per use - the user sets the duration of the heating cycle and 

how many hours from now the heating cycle begins. The timer does NOT repeat 

until reset. 

Содержание IBIZA KASPABWIBZA

Страница 1: ...IBIZA INFLATABLE PORTABLE OUTDOOR HOTTUB MASSAGE SPA 4 6 PERSONS KASPABWIBZA...

Страница 2: ......

Страница 3: ...INJURY Do not operate spa if inlet or outlet pipes are broken or missing Never attempt to replace the inlet and outlet pipes Contact help kogan com for assistance Risk of electric shock Install at lea...

Страница 4: ...ated or fixed so that they cannot fall into the spa pool The plug of the pump shall be more than 3 5 metres away from the spa at all times It is necessary to have the plug accessible after installatio...

Страница 5: ...cation can greatly increase the risk of fatal hyperthermia Hyperthermia occurs when the internal temperature of the body reaches a level that is several degrees above the normal body temperature of 37...

Страница 6: ...xit the spa slowly and cautiously Wet surfaces are slippery To avoid damage to the pump the spa must never be operated unless the spa is filled with water Immediately leave spa if the user feels uncom...

Страница 7: ...Filter cartridge x2 13 P61726ASS18 x1 14 P61727ASS18 x1 15 P05346 x1 16 P6609ASS16 x1 17 P05347 x1 COMPONENTS Note Examine equipment before use Notify Kogan com support of any damaged or missing parts...

Страница 8: ...requirements if you install the spa indoors Humidity is a natural side effect with spa installation Determine the effects of airborne moisture on surfaces exposed wood paper etc in the proposed locati...

Страница 9: ...r Position the spa liner outdoor in the desired position connect the spa heater and fill with water Important The water temperature used to fill the spa must be above 6 C otherwise when you begin to o...

Страница 10: ...Step 1 Step 2 Step 3 Step 4 Inflation time for reference only may not be exact INSTALLATION P6609ASS16...

Страница 11: ...Step 5 Step 6 Step 7 Step 8 Step 9 Step 10 Step 11...

Страница 12: ...ipment and surrounding items The spa is a class I electrical appliance and must be connected directly to a grounded socket It is recommended to only use a socket which is resistant to humidity and cap...

Страница 13: ...inflating you will notice that air will be expelled from the area where the air hose connects to the pump this is normal for technique requirements Important Don t cover the holes on the base of the...

Страница 14: ...pa A Lock Unlock Button F On Off Button B Power Saving Timer Button G Temperature Decrease C Heat Button H Celsius Fahrenheit Toggle D Massage System Button I Water Filter Button E Temperature Increas...

Страница 15: ...10 seconds to confirm the setting The 0 LED will light steadily and the countdown to heater activation will begin To modify the timer settings Press the button and use the or button to adjust Cancel...

Страница 16: ...button for 2 seconds to active the control panel buttons and the light turns to green Press this button for 2 seconds to turn off all currently activated functions H CELSIUS FAHRENHEITTOGGLE The tempe...

Страница 17: ...er a long period of inactivity be sure to press the reset button on the pump using a small and thin object If the temperature on the control panel or the water temperature has not changed 4 5 hours af...

Страница 18: ...cover the spa with the spa cover whenever the heating function is activated Leaving the spa uncovered will increase the heating duration required When the spa is assembled with water do not switch off...

Страница 19: ...please block the hoses to prevent water from escaping then disconnect the pump screw on the cap P00217 to avoid water coming out from the air pipe Cover Maintenance The cover shall be cleaned inside...

Страница 20: ...mistry and chlorine or bromine tablets do not use granules with the chemical dispenser Water quality will be directly related to frequency of use number of users and overall maintenance of the spa The...

Страница 21: ...Alkalinity Free Chlorine 7 4 7 6 80 120ppm 2 4ppm Note Damage resulting from chemical imbalance is not covered by the warranty Pool chemicals are potentially toxic and should be handled with care Ther...

Страница 22: ...o extend the life of the spa We recommend using the pump to blow dry the spa pump and pipes Remove the filter sets and discard the used filter cartridges Re attach the two stopper caps onto the spa s...

Страница 23: ...el patch 3 Press patch over area to be repaired 4 Wait 30 seconds before inflation ForTritech PVC material If the spa is torn or punctured use the provided PVC repair patch and glue not included follo...

Страница 24: ...pump and wait two hours until the pump has cooled Insert the plug and press the Massage System Button Press the Massage System Button to reactivate Pump adapters are not level with the spa adapters O...

Страница 25: ...nance Pay close attention to the chemical manufacturer s instructions Water leaks from the adapters between the pump and spa Seals are missing inside the pump adapters Seals are not in the correct pos...

Страница 26: ...rs The washers within the spa couplings may have become perished or worn Remove the 2 stopper caps before heating refer to Installation section of this user guide Remove the filter set from inside the...

Страница 27: ...pump push the pump s reset button The pump s thermometer connections have issues The pump s thermometer connectors are not working The pump s thermometer is broken Contact kogan com for support The ma...

Страница 28: ...Capacity 4 6 adults Dimensions 1 80 m x 1 80 m x 66 cm Inflation pressure 0 8 PSI 0 055 Bar Litres 778 L SPECIFICATIONS...

Страница 29: ...NOTES...

Страница 30: ......

Страница 31: ......

Страница 32: ...ion We hope that this user guide has given you the assistance needed for a simple set up For the most up to date guide for your product as well as any additional assistance you may require head online...

Отзывы: